Homogeneous electrogenerated chemiluminescence immunoassay using a luminol-labeled digoxin hapten

被引:10
作者
Zhang, CX [1 ]
Zhang, HH [1 ]
Feng, ML [1 ]
机构
[1] Shaanxi Normal Univ, Sch Chem & Mat Sci, Dept Chem, Xian 710062, Peoples R China
基金
中国国家自然科学基金;
关键词
electrogenerated chemiluminescence; immunoassay; digoxin; luminol;
D O I
10.1081/AL-120020146
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel homogeneous electrogenerated chemiluminescence (ECL) immunoassay for digoxin antibody and digoxin hapten was developed using a luminol-labeled digoxin hapten. ECL emission was electrochemically generated from the luminol-labeled digoxin and decreased markedly in the presence of anti-digoxin antibody due to steric hindrance. The anti-digoxin antibody concentration was determined in the range from 115000 to 11500 dilution. Digoxin hapten was determined throughout its therapeutic range with a detection limit of 0.10ng/mL and in a three orders of magnitude range by competitive immunoreaction between luminol-labeled digoxin and digoxin with fixed quantity of anti-digoxin antibody. The proposed method has been applied to determine anti-digoxin antibody and digoxin in human control serum with satisfactory results.
引用
收藏
页码:1103 / 1114
页数:12
相关论文
共 13 条
[1]   Determination of human serum albumin by chemiluminescence immunoassay with luminol using a platinum-immobilized flow-cell [J].
Aoyagi, S ;
Iwata, T ;
Miyasaka, T ;
Sakai, K .
ANALYTICA CHIMICA ACTA, 2001, 436 (01) :103-108
[2]   An electrochemiluminescence flow through-cell and its applications to sensitive immunoassay using N-(aminobutyl)-N-ethylisoluminol [J].
Arai, K ;
Takahashi, K ;
Kusu, F .
ANALYTICAL CHEMISTRY, 1999, 71 (11) :2237-2240
[3]  
BLACKBURN GF, 1991, CLIN CHEM, V37, P1534
[4]   Application of redox enzymes for probing the antigen-antibody association at monolayer interfaces: Development of amperometric immunosensor electrodes [J].
Blonder, R ;
Katz, E ;
Cohen, Y ;
Itzhak, N ;
Riklin, A ;
Willner, I .
ANALYTICAL CHEMISTRY, 1996, 68 (18) :3151-3157
[5]  
Chen GN, 2000, TALANTA, V50, P1275
[6]  
COUSINO MA, 1997, ANAL CHEM, V69, pA545
[7]   Electrogenerated chemiluminescence of methyl-9-(p-formylphenyl) acridinium carboxylate fluorosulfonate and its applications to immunoassay [J].
Lin, JM ;
Yamada, M .
MICROCHEMICAL JOURNAL, 1998, 58 (01) :105-116
[8]   Electrochemiluminescence of luminol for 2,4-D optical immunosensing in a flow injection analysis system [J].
Marquette, CA ;
Blum, LJ .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 51 (1-3) :100-106
[9]  
MYUNG JC, 1999, MICROCHEM J, V63, P92
[10]   ELECTROCHEMILUMINESCENCE OF HYDROGEN-PEROXIDE LUMINOL AT A CARBON ELECTRODE [J].
SAKURA, S .
ANALYTICA CHIMICA ACTA, 1992, 262 (01) :49-57