Red cell transfusion practice following the transfusion requirements in critical care (TRICC) study: prospective observational cohort study in a large UK intensive care unit

被引:58
作者
Chohan, SS
McArdle, F
McClelland, DBL
Mackenzie, SJ
Walsh, TS
机构
[1] Royal Infirm, Dept Anaesthesia Crit Care & Pain Med, Edinburgh EH3 9YW, Midlothian, Scotland
[2] Royal Infirm, Scottish Natl Blood Transfus Serv, Edinburgh, Midlothian, Scotland
关键词
anaemia; critical illness; red cells; transfusion; trigger;
D O I
10.1046/j.1423-0410.2003.00284.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objectives The Transfusion Requirements In Critical Care (TRICC) study found that critically ill patients tolerate a restrictive haemoglobin transfusion threshold. We investigated red-cell transfusion practice since publication of the TRICC study in a large Scottish teaching hospital intensive care unit (ICU). Materials and Methods We prospectively collected daily data for a 6-month period on haemoglobin concentrations, red-cell transfusions and indications for transfusions, throughout ICU stay for all patients who stayed for longer than 24 h in the ICU. Results A total of 176 patients were studied, who utilized 1237 ICU days. Of these 176 patients, 52% received red-cell transfusions. A haemoglobin concentration of less than or equal to 9 g/dl was measured in 55% of patients; this occurred by day 1 and day 2 in 52% and 77% of these cases, respectively. Overall the haemoglobin concentration was less than or equal to 9 g/dl for 45% of all patient days. Total red-cell use was 3.1 units per admission (0.47 units per patient day). Only 18% of transfusion episodes were required as a result of haemorrhage. For 'non-haemorrhage' transfusion episodes, the median pretransfusion haemoglobin concentration was 7.8 g/dl (interquartile range: 7.4-8.4 g/dl), and 64% of transfusion episodes were for 2 units. Conclusions Clinicians in our centre were conservative, in keeping with recent transfusion guidelines, but deviated from the TRICC protocol by transfusing at haemoglobin concentrations of between 7 and 9 g/dl, rather than below 7 g/dl, and by prescribing 2 unit transfusions. Significant numbers of red-cell units are still used in the critically ill.
引用
收藏
页码:211 / 218
页数:8
相关论文
共 20 条
[1]  
*ASS AN GREAT BRIT, BLOOD TRANSF AN
[2]   Efficacy of recombinant human erythropoietin in the critically ill patient: A randomized, double-blind, placebo-controlled trial (Reprinted from Critical Care Medicine, vol 27, pg 2346-2350, 1999) [J].
Corwin, HL ;
Gettinger, A ;
Rodriguez, RM ;
Pearl, RG ;
Gubler, KD ;
Enny, C ;
Colton, T ;
Corwin, MJ .
CRITICAL CARE MEDICINE, 2001, 29 (09) :S201-S205
[3]   RBC TRANSFUSION IN THE ICU - IS THERE A REASON [J].
CORWIN, HL ;
PARSONNET, KC ;
GETTINGER, A .
CHEST, 1995, 108 (03) :767-771
[4]   Efficacy of recombinant human erythropoietin in the critically ill patient: A randomized, double-blind, placebo-controlled trial [J].
Corwin, HL ;
Gettinger, A ;
Rodriguez, RM ;
Pearl, RG ;
Gubler, KD ;
Enny, G ;
Colton, T ;
Corwin, MJ .
CRITICAL CARE MEDICINE, 1999, 27 (11) :2346-2350
[5]   Serial evaluation of the SOFA score to predict outcome in critically ill patients [J].
Ferreira, FL ;
Bota, DP ;
Bross, A ;
Mélot, C ;
Vincent, JL .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2001, 286 (14) :1754-1758
[6]   Appropriateness of red blood cell transfusion in Australasian intensive care practice [J].
French, CJ ;
Bellomo, R ;
Finfer, SR ;
Lipman, J ;
Chapman, M ;
Boyce, NW .
MEDICAL JOURNAL OF AUSTRALIA, 2002, 177 (10) :548-551
[7]  
Hebert PC, 1998, CRIT CARE MED, V26, P482, DOI 10.1097/00003246-199803000-00019
[8]   Is a low transfusion threshold safe in critically ill patients with cardiovascular diseases? [J].
Hébert, PC ;
Yetisir, E ;
Martin, C ;
Blajchman, MA ;
Wells, G ;
Marshall, J ;
Tweeddale, M ;
Pagliarello, G ;
Schweitzer, I .
CRITICAL CARE MEDICINE, 2001, 29 (02) :227-234
[9]   A multicenter, randomized, controlled clinical trial of transfusion requirements in critical care [J].
Hébert, PC ;
Wells, G ;
Blajchman, MA ;
Marshall, J ;
Martin, C ;
Pagliarello, G ;
Tweeddale, M ;
Schweitzer, I ;
Yetisir, E .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 340 (06) :409-417
[10]   Do blood transfusions improve outcomes related to mechanical ventilation? [J].
Hébert, PC ;
Blajchman, MA ;
Cook, DJ ;
Yetisir, E ;
Wells, G ;
Marshall, J ;
Schweitzer, I .