Comparative study of capillary electroendosmotic chromatography and electrically assisted gradient nano-liquid chromatography for the separation of peptides

被引:40
作者
Adam, T
Unger, KK
机构
[1] Bayer AG, PH, OP, Elb,QW, D-42096 Wuppertal, Germany
[2] Johannes Gutenberg Univ Mainz, Inst Anorgan Chem & Analyt Chem, D-55099 Mainz, Germany
关键词
electrokinetic chromatography; gradient elution; electrically assisted gradient elution; mixed-mode chromatography; peptides;
D O I
10.1016/S0021-9673(00)00367-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Capillary electroendoendosmotic chromatography (CEC), being a hybrid of high-performance liquid chromatography (HPLC) and capillary electrophoresis, offers considerable changes to enhance column efficiency, speed of analysis and additional selectivity as compared to the parent methods. The analytes are driven by the electroendosmotic flow (EOF) and separated by surface-solute interactions as well as by differences in electromigration. In this paper on the separation of peptides on C-18 reversed-phase and mixed-mode (sulphonic acid-n-alkyl) packings in CEC and electrically assisted reversed-phase gradient nano-LC are investigated. It is shown that mixed mode packings generate a higher EOF than reversed-phase packings that is scarcely dependent on the pH of the eluent. Applying a potential in gradient elution reversed-phase nano-LC of peptides shortens the analysis time as compared to separations without a potential. Electrically assisted reversed-phase gradient elution nano-LC is a powerful separation tool for analysis of tryptic digests. Peptides can be successfully resolved in acidic organic mobile phase at pH 2-3 with and without trifluoroacid as ion pairing reagent under isocratic conditions. It is demonstrated that CEC with mixed mode packing and an eluent of pH 2.3 with varying acetonitrile content can be applied to monitor impurities in a synthetic peptide. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:241 / 251
页数:11
相关论文
共 22 条
[1]  
ADAM T, 1998, THESIS J GUTENBERG U
[2]  
APFEL A, 1997, 17 INT S SEP AN PROT
[3]   Sintered octadecylsilica as monolithic column packing in capillary electrochromatography and micro high-performance liquid chromatography [J].
Asiaie, R ;
Huang, X ;
Farnan, D ;
Horváth, C .
JOURNAL OF CHROMATOGRAPHY A, 1998, 806 (02) :251-263
[4]   DEVELOPMENT OF AN INSTRUMENTAL CONFIGURATION FOR PSEUDO-ELECTROCHROMATOGRAPHY ELECTROSPRAY MASS-SPECTROMETRY [J].
DEKKERS, SEG ;
TJADEN, UR ;
VANDERGREEF, J .
JOURNAL OF CHROMATOGRAPHY A, 1995, 712 (01) :201-209
[5]  
DITTMANN M, 1995, LC GC, V13, P135
[6]  
Dittmann MM, 1997, J MICROCOLUMN SEP, V9, P399, DOI 10.1002/(SICI)1520-667X(1997)9:5<399::AID-MCS6>3.0.CO
[7]  
2-X
[8]   Selectivity tuning in pressurized-flow electrochromatography [J].
Eimer, T ;
Unger, KK ;
vanderGreef, J .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (09) :463-468
[9]  
Euerby MR, 1997, J MICROCOLUMN SEP, V9, P373
[10]  
Euerby MR, 1998, LC GC-MAG SEP SCI, V16, P386