Chronic neural stimulation with thin-film, iridium oxide electrodes

被引:197
作者
Weiland, JD
Anderson, DJ
机构
[1] Johns Hopkins Univ, Wilmer Eye Inst, Baltimore, MD 21287 USA
[2] Univ Michigan, Ann Arbor, MI 48109 USA
关键词
electrical stimulation; impedance spectroscopy; iridium oxide; neural prosthesis; stimulating electrodes;
D O I
10.1109/10.846685
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Experiments were conducted to assess the effect of chronic stimulation on the electrical properties of the electrode-tissue system, as measured using electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). Silicon, micromachined probes with multiple iridium oxide stimulating electrodes (400-1600 mu m(2)) were implanted in guinea pig cortex, A 10-17 day post-operative recovery period was followed by five days of monopolar stimulation, two hours/electrode each day using biphasic, constant current stimulation (5-100 mu A, 100 mu s/phase). EIS and CV-data were taken before and after stimulation. The post-stimulation impedance [at mid-range frequencies (100 Hz-100 kHz)] consistently and significantly decreased relative to prestimulation levels. Impedance magnitude increased permanently at low frequencies (<100 Hz), correlating to a change in the charge storage capacity (the area under a cyclic voltammagram). Impedance magnitude significantly increased during the recovery period, though this increase could be mostly reversed by applying small currents, A mathematical model of the electrode-tissue system impedance was used to analyze in vivo behavior, The data and modeling results shows that applying charge to the electrode can consistently reduce the impedance of the electrode-tissue system, Analysis of explanted probes suggests that the interaction between the tissue and electrode is dependent on whether chronic pulses were applied. It is hypothesized that the interface between the tissue and metal is altered by current pulsing, resulting in a temporary impedance shift.
引用
收藏
页码:911 / 918
页数:8
相关论文
共 30 条
[1]   HISTOPATHOLOGIC EVALUATION OF PROLONGED INTRACORTICAL ELECTRICAL-STIMULATION [J].
AGNEW, WF ;
YUEN, TGH ;
MCCREERY, DB ;
BULLARA, LA .
EXPERIMENTAL NEUROLOGY, 1986, 92 (01) :162-185
[2]   BATCH-FABRICATED THIN-FILM ELECTRODES FOR STIMULATION OF THE CENTRAL AUDITORY-SYSTEM [J].
ANDERSON, DJ ;
NAJAFI, K ;
TANGHE, SJ ;
EVANS, DA ;
LEVY, KL ;
HETKE, JF ;
XUE, XL ;
ZAPPIA, JJ ;
WISE, KD .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (07) :693-704
[3]  
[Anonymous], 1970, ELECTROANALYTICAL CH
[4]   IMPEDANCE OF HYDRATED IRIDIUM OXIDE ELECTRODES [J].
AURIANBLAJENI, B ;
BEEBE, X ;
RAUH, RD ;
ROSE, TL .
ELECTROCHIMICA ACTA, 1989, 34 (06) :795-802
[5]   THE NUMERICAL INVERSION OF THE LAPLACE TRANSFORM APPLIED TO IMPEDANCE SPECTROSCOPY [J].
AURIANBLAJENI, B .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 1992, 22 (06) :553-557
[6]   CHARGE INJECTION LIMITS OF ACTIVATED IRIDIUM OXIDE ELECTRODES WITH 0.2MS PULSES IN BICARBONATE BUFFERED SALINE [J].
BEEBE, X ;
ROSE, TL .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (06) :494-495
[7]   CRITERIA FOR SELECTING ELECTRODES FOR ELECTRICAL-STIMULATION - THEORETICAL AND PRACTICAL CONSIDERATIONS [J].
BRUMMER, SB ;
ROBBLEE, LS ;
HAMBRECHT, FT .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1983, 405 (JUN) :159-171
[8]   ELECTRICAL-STIMULATION OF NERVOUS-SYSTEM - PRINCIPLE OF SAFE CHARGE INJECTION WITH NOBLE-METAL ELECTRODES [J].
BRUMMER, SB ;
TURNER, MJ .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1975, 2 (01) :13-25
[9]  
CONWAY BE, 1991, J ELECTROCHEM SOC, V138, P1538
[10]   Historical evolution of circuit models for the electrode-electrolyte interface [J].
Geddes, LA .
ANNALS OF BIOMEDICAL ENGINEERING, 1997, 25 (01) :1-14