In recent years, new generation spectrophotometers are increasingly used in biomedical applications. Handheld spectrophotometers, offering compactness, versatility, and low cost, have facilitated a broad array of applications in biomedical optics. However, despite the popularity and the diverse range of applications, a detailed characterization of many of these new spectrophotometers in terms of stray light and noise characteristics is missing from the literature. Such a popular instrument (USB2000) is characterized in detail with particular focus and emphasis on its noise and stray light characteristics. The results of the analysis may be useful to numerous users of this and other similar instruments in a diverse range of applications. (C) 2010 Optical Society of America
引用
收藏
页码:163 / 169
页数:7
相关论文
共 16 条
[1]   Optical Reflectance Spectroscopy to Differentiate Benign From Malignant Renal Tumors at Surgery [J].
Bensalah, Karim ;
Peswani, Disha ;
Tuncel, Altug ;
Raman, Jay D. ;
Zeltser, Ilia ;
Liu, Hanli ;
Cadeddu, Jeffrey .
UROLOGY, 2009, 73 (01) :178-181
[2]   The role of optical spectroscopy in epilepsy surgery in children [J].
Bhatia, Sanjiv ;
Ragheb, John ;
Johnson, Mahlon ;
Oh, Sanghoon ;
Sandberg, David I. ;
Lin, Wei-Chiang .
NEUROSURGICAL FOCUS, 2008, 25 (03)
[3]   PORTABLE LASER SPECTROFLUOROMETER SYSTEM FOR IN-VIVO HUMAN TISSUE FLUORESCENCE STUDIES [J].
BRENNAN, JF ;
ZONIOS, GI ;
WANG, TD ;
RAVA, RP ;
HAYES, GB ;
DASARI, RR ;
FELD, MS .
APPLIED SPECTROSCOPY, 1993, 47 (12) :2081-2086
[4]   Stray-light correction algorithm for spectrographs [J].
Brown, SW ;
Johnson, BC ;
Feinholz, ME ;
Yarbrough, MA ;
Flora, SJ ;
Lykke, KR ;
Clark, DK .
METROLOGIA, 2003, 40 (01) :S81-S84
[5]   Differentiation of melanoma from non-cancerous tissue in an animal model using elastic light single-scattering spectroscopy [J].
Canpolat, Murat ;
Gokhan, A. Guzide ;
Ciftcioglu, M. Akif ;
Erin, Nuray .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2008, 7 (03) :235-240
[6]   Clinical ultraviolet dosimetry with a CCD monochromator array spectroradiometer [J].
Coleman, Andrew ;
Sarkany, Robert ;
Walker, Susan .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (18) :5239-5255
[7]   A model for measurement of noise in CCD digital-video cameras [J].
Irie, K. ;
McKinnon, A. E. ;
Unsworth, K. ;
Woodhead, I. M. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2008, 19 (04)
[8]   Determination of reduced scattering coefficient of biological tissue from a needle-like probe [J].
Johns, M ;
Giller, CA ;
German, DC ;
Liu, HL .
OPTICS EXPRESS, 2005, 13 (13) :4828-4842
[9]   Reflection spectroscopy of atherosclerotic plaque [J].
Lilledahl, Magnus B. ;
Haugen, Olav A. ;
Barkost, Marianne ;
Svaasand, Lars O. .
JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (02)
[10]   The use of diode array spectroradiometers for dosimetry in phototherapy [J].
Oliver, H ;
Moseley, H .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (24) :4411-4421