Dose to contralateral breast: A comparison of four primary breast irradiation techniques

被引:50
作者
Kelly, CA
Wang, XY
Chu, JCH
Hartsell, WF
机构
[1] MEMPHIS UNIV,DEPT RADIAT ONCOL,MEMPHIS,TN 38103
[2] RUSH PRESBYTERIAN ST LUKES MED CTR,DEPT RADIAT ONCOL,CHICAGO,IL 60612
[3] RUSH UNIV,CHICAGO,IL 60612
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1996年 / 34卷 / 03期
关键词
breast irradiation; treatment planning; contralateral breast dose;
D O I
10.1016/0360-3016(95)02051-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Contralateral breast dose from primary breast irradiation has been implicated in the risk of second breast malignancies, It has previously been shown that the use of half-beam blocking can increase the opposite breast dose by a factor of five, This study evaluates four different breast treatment techniques to compare radiation dose to the contralateral breast. Methods and Materials: Dose measurements were made using thermoluminescent dosimeters (TLD) capsules, which were placed in the Rando phantom in the following locations in the contralateral breast: seven along the central axis plane, one at 5 cm superior to, and one 5 cm inferior to the central axis plane. One TLD capsule was placed in the midcenter of the treated breast, The following radiation techniques were used: (a) half-beam with a custom block (HB+CB), (b) half-beam using asymmetric collimator jaw (HB/AJ), (c) half-beam using asymmetric collimator jaw with custom block (H/AJ+CB), and (d) isocentric technique with nondivergent posterior borders [Joint Center for Radiation Therapy (JCRT) technique], For each technique, isodose distributions for the Rando phantom were optimized using (a) 15 degree medial and lateral compensating wedges, and (b) a single 30 degree lateral compensating wedge, The phantom was treated with 6 MV photons, Each technique was repeated six times, and the TLD readings were averaged. Results: The custom cerrobend half-beam block technique gives the highest contralateral breast dose, regardless of wedge, The remaining techniques give results in a similar range, with the asymmetric jaw with no medial wedge technique giving the lowest total dose (p = not significant), The use of a medial wedge increases the opposite breast dose for all techniques, The asymmetric half-beam technique gives significantly less dose than the cerrobend half-beam technique, due to decreased transmission through the asymmetric collimators, The asymmetric jaw vs, JCRT technique results in similar contralateral breast dose. Conclusions: As expected, dose to the contralateral breast increases with the use of a medial wedge. Cerrobend half-beam blocking gives the highest opposite breast dose, The lowest contralateral breast dose is with the asymmetric jaw with no medial wedge and no block, The asymmetric jaw technique with block yields equivalent contralateral breast doses to the JCRT technique.
引用
收藏
页码:727 / 732
页数:6
相关论文
共 6 条
[1]   CANCER IN THE CONTRALATERAL BREAST AFTER RADIOTHERAPY FOR BREAST-CANCER [J].
BOICE, JD ;
HARVEY, EB ;
BLETTNER, M ;
STOVALL, M ;
FLANNERY, JT .
NEW ENGLAND JOURNAL OF MEDICINE, 1992, 326 (12) :781-785
[2]   ARE COSMETIC RESULTS FOLLOWING CONSERVATIVE SURGERY AND RADIATION-THERAPY FOR EARLY BREAST-CANCER DEPENDENT ON TECHNIQUE [J].
DELAROCHEFORDIERE, A ;
ABNER, AL ;
SILVER, B ;
VICINI, F ;
RECHT, A ;
HARRIS, JR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 23 (05) :925-931
[3]   DOSE TO THE CONTRALATERAL BREAST DUE TO PRIMARY BREAST IRRADIATION [J].
FRAASS, BA ;
ROBERSON, PL ;
LICHTER, AS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1985, 11 (03) :485-497
[4]   TECHNIQUE FOR BREAST IRRADIATION USING CUSTOM BLOCKS CONFORMING TO THE CHEST-WALL CONTOUR [J].
HARTSELL, WF ;
MURTHY, AK ;
KIEL, KD ;
KAO, M ;
HENDRICKSON, FR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 19 (01) :189-195
[5]   3-FIELD TECHNIQUE FOR BREAST IRRADIATION USING TANGENTIAL FIELD CORNER BLOCKS [J].
SIDDON, RL ;
BUCK, BA ;
HARRIS, JR ;
SVENSSON, GK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1983, 9 (04) :583-588
[6]   COMPARISON OF CONTRALATERAL BREAST DOSES FROM 1/2 BEAM BLOCK AND ISOCENTRIC TREATMENT TECHNIQUES FOR PATIENTS TREATED WITH PRIMARY BREAST IRRADIATION WITH CO-60 [J].
TERCILLA, O ;
KRASIN, F ;
LAWNTSAO, L .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 17 (01) :205-210