Comparison between traditional 2-dimensional cephalometry and a 3-dimensional approach on human dry skulls

被引:234
作者
Adams, GL
Gansky, SA
Miller, AJ
Harrell, WE
Hatcher, DC
机构
[1] Univ Calif San Francisco, Sch Dent, Dept Growth & Dev, Div Orthodont, San Francisco, CA 94143 USA
[2] Univ Calif San Francisco, Dept Prevent & Restorat Dent Sci, Div Oral Epidemiol & Dent Publ Hlth, San Francisco, CA 94143 USA
[3] Diagnost Digital Imaging, Sacramento, CA USA
关键词
D O I
10.1016/j.ajodo.2004.03.023
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
The cephalogram is the standard used by orthodontists to assess skeletal, dental, and soft tissue relationships. This approach, however, is based on 2-dimensional (2D) views used to analyze 3-dimensional (3D) objects. The purpose of this project was to evaluate and compare a 3D imaging system and traditional 2D cephalometry for accuracy in recording the anatomical truth as defined by physical measurements with a calibrated caliper. Thirteen skeletal landmarks were located by both radiographic methods on 9 dry human skulls. Intraclass correlation (0.995), variance (0.054 mm(2)), and standard deviation (SD) (0.237 mm) were averaged over 76 measurements and derived from precision calipers to establish these physical measurements as a reliable gold standard to make comparisons of the 2D and 3D radiographic methods. The results showed great variability of the 2D from the gold standard, with the range varying from -17.68 mm (underestimation of Gn-Zyg R) to +15.52 mm (overestimation of Zyg L-Zyg R). In contrast, the 3D method (Sculptor, Glendora, Calif) indicated a range of the SD from -3.99 (underestimation) mm to +2.96 mm (overestimation). The 3D evaluation was much more precise, within approximately 1 mm of the gold standard. These results indicate that, when the actual distance is measured on a human skull in its true dimensions of 3D space, the Sculptor program, by using a 3D method, is more precise and 4 to 5 times more accurate than the 2D approach. Evaluating distances in 3D space with a 2D image grossly exaggerates the true measure and offers a distorted view of craniofacial growth. There is an inherent problem of representing a linear measure occupying a 3D space with a 2D image.
引用
收藏
页码:397 / 409
页数:13
相关论文
共 52 条
[1]
ADAMS GL, 2000, THESIS U CALIFORNIA
[2]
[Anonymous], ANGLE ORTHODONTIST
[3]
RELIABILITY OF HEAD FILM MEASUREMENTS .1. LANDMARK IDENTIFICATION [J].
BAUMRIND, S ;
FRANTZ, RC .
AMERICAN JOURNAL OF ORTHODONTICS, 1971, 60 (02) :111-&
[4]
DIRECT AND CT MEASUREMENTS OF CANALS AND FORAMINA OF THE SKULL BASE [J].
BERLIS, A ;
PUTZ, R ;
SCHUMACHER, M .
BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (776) :653-661
[5]
MEASUREMENT ON RADIOGRAPHS [J].
BJORK, A ;
SOLOW, B .
JOURNAL OF DENTAL RESEARCH, 1962, 41 (03) :672-&
[6]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]
Broadbent BH., 1931, Angle Orthod, V1, P45, DOI DOI 10.1043/0003-3219(1931)001<0045:ANXTAI>2.0.CO
[8]
2
[9]
BRODIE A. G., 1949, JOUR ORAL SURG, V7, P185
[10]
STEREOPHOTOGRAMMETRY OF FACE - A PRELIMINARY INVESTIGATION INTO ACCURACY OF A SIMPLIFIED SYSTEM EVOLVED FOR CONTOUR MAPPING BY PHOTOGRAPHY [J].
BURKE, PH ;
BEARD, LFH .
AMERICAN JOURNAL OF ORTHODONTICS, 1967, 53 (10) :769-&