Rapid 3D Phenotyping of Cardiovascular Development in Mouse Embryos by Micro-CT With Iodine Staining

被引:213
作者
Degenhardt, Karl [1 ,2 ,4 ]
Wright, Alexander C. [3 ]
Horng, Debra [3 ]
Padmanabhan, Arun [1 ,2 ]
Epstein, Jonathan A. [1 ,2 ]
机构
[1] Univ Penn, Dept Cell & Dev Biol, Penn Cardiovasc Inst, Philadelphia, PA 19104 USA
[2] Univ Penn, Inst Regenerat Med, Philadelphia, PA 19104 USA
[3] Univ Penn, Med Ctr, Lab Struct NMR Imaging, Dept Radiol, Philadelphia, PA 19104 USA
[4] Childrens Hosp Philadelphia, Dept Pediat, Div Cardiol, Philadelphia, PA 19104 USA
基金
美国国家卫生研究院;
关键词
micro-CT; iodine; mouse; development; PlexinD1; congenital heart disease; MICROCOMPUTED TOMOGRAPHY; CARDIAC DEVELOPMENT; HIGH-THROUGHPUT; HISTOLOGY; CELLS;
D O I
10.1161/CIRCIMAGING.109.918482
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Microcomputed tomography (micro-CT) has been used extensively in research to generate high-resolution 3D images of calcified tissues in small animals nondestructively. It has been especially useful for the characterization of skeletal mutations but limited in its utility for the analysis of soft tissue such as the cardiovascular system. Visualization of the cardiovascular system has been largely restricted to structures that can be filled with radiopaque intravascular contrast agents in adult animals. Recent ex vivo studies using osmium tetroxide, iodinated contrast agents, inorganic iodine, and phosphotungstic acid have demonstrated the ability to stain soft tissues differentially, allowing for high intertissue contrast in micro-CT images. In the present study, we demonstrate the application of this technology for visualization of cardiovascular structures in developing mouse embryos using Lugol solution (aqueous potassium iodide plus iodine). Methods and Results-We show the optimization of this method to obtain ex vivo micro-CT images of embryonic and neonatal mice with excellent soft-tissue contrast. We demonstrate the utility of this method to visualize key structures during cardiovascular development at various stages of embryogenesis. Our method benefits from the ease of sample preparation, low toxicity, and low cost. Furthermore, we show how multiple cardiac defects can be demonstrated by micro-CT in a single specimen with a known genetic lesion. Indeed, a previously undescribed cardiac venous abnormality is revealed in a PlexinD1 mutant mouse. Conclusions-Micro-CT of iodine-stained tissue is a valuable technique for the characterization of cardiovascular development and defects in mouse models of congenital heart disease. (Circ Cardiovasc Imaging. 2010; 3: 314-322.)
引用
收藏
页码:314 / U138
页数:21
相关论文
共 36 条
[1]   NMR imaging of the diffusion of water at 37 °C into poly(2-hydroxyethyl methacrylate) containing aspirin or vitamin B12 [J].
Chowdhury, MA ;
Hill, DJT ;
Whittaker, AK .
BIOMACROMOLECULES, 2004, 5 (03) :971-976
[2]  
Crank J., 1979, MATH DIFFUSION, V2
[3]   3D micro-CT imaging of the postmortem brain [J].
de Crespigny, Alex ;
Bou-Reslan, Hani ;
Nishimura, Merry C. ;
Phillips, Heidi ;
Carano, Richard A. D. ;
D'Arceuil, Helen E. .
JOURNAL OF NEUROSCIENCE METHODS, 2008, 171 (02) :207-213
[4]   Human Cardiac Development in the First Trimester A High-Resolution Magnetic Resonance Imaging and Episcopic Fluorescence Image Capture Atlas [J].
Dhanantwari, Preeta ;
Lee, Elaine ;
Krishnan, Anita ;
Samtani, Rajeev ;
Yamada, Shigehito ;
Anderson, Stasia ;
Lockett, Elizabeth ;
Donofrio, Mary ;
Shiota, Kohei ;
Leatherbury, Linda ;
Lo, Cecilia W. .
CIRCULATION, 2009, 120 (04) :343-U126
[5]   HIGH SPATIAL-RESOLUTION IMAGING OF BONE-MINERAL USING COMPUTED MICROTOMOGRAPHY - COMPARISON WITH MICRORADIOGRAPHY AND UNDECALCIFIED HISTOLOGIC SECTIONS [J].
ENGELKE, K ;
GRAEFF, W ;
MEISS, L ;
HAHN, M ;
DELLING, G .
INVESTIGATIVE RADIOLOGY, 1993, 28 (04) :341-349
[6]   Micro-Computed Tomographical Imaging of Soft Biological Materials Using Contrast Techniques [J].
Faraj, Kaeuis A. ;
Cuijpers, Vincent M. J. I. ;
Wismans, Ronnie G. ;
Walboomers, X. Frank ;
Jansen, John A. ;
van Kuppevelt, Toin H. ;
Daamen, Willeke F. .
TISSUE ENGINEERING PART C-METHODS, 2009, 15 (03) :493-499
[7]   Fundamental image quality limits for microcomputed tomography in small animals [J].
Ford, NL ;
Thornton, MM ;
Holdsworth, DW .
MEDICAL PHYSICS, 2003, 30 (11) :2869-2877
[8]   ECHOCARDIOGRAPHIC ASSESSMENT OF LEFT-VENTRICULAR MASS AND SYSTOLIC FUNCTION IN MICE [J].
GARDIN, JM ;
SIRI, FM ;
KITSIS, RN ;
EDWARDS, JG ;
LEINWAND, LA .
CIRCULATION RESEARCH, 1995, 76 (05) :907-914
[9]   K-edge subtraction using an energy-resolving position-sensitive detector [J].
Gillam, John E. ;
Kitcher, Daniel ;
Beveridge, Toby E. ;
Midgley, Stewart ;
Hall, Chris ;
Lewis, Rob A. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 604 (1-2) :97-100
[10]   PlexinD1 and semaphorin signaling are required in endothelial cells for cadiovascular development [J].
Gitler, AD ;
Lu, MM ;
Epstein, JA .
DEVELOPMENTAL CELL, 2004, 7 (01) :107-116