Pitfalls in lymph node staging with positron emission tomography in non-small cell lung cancer patients

被引:102
作者
Takamochi, K [1 ]
Yoshida, J
Murakami, K
Niho, S
Ishii, G
Nishimura, M
Nishiwaki, Y
Suzuki, K
Nagai, K
机构
[1] Natl Canc Ctr Hosp E, Dept Thorac Oncol, Chiba, Japan
[2] Hamamatsu Univ Sch Med, Dept Surg 1, Hamamatsu, Shizuoka 4313192, Japan
[3] Natl Canc Ctr, Res Inst E, Div Pathol, Chiba, Japan
[4] Natl Canc Ctr Hosp E, Dept Radiol, Chiba, Japan
关键词
non-small cell lung cancer; positron emission tomography; diagnosis; staging; false-positive; false-negative;
D O I
10.1016/j.lungcan.2004.08.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: The evidence of clinical value of positron emission tomography (PET) with fluorine-18 fluorodeoxyglucose (FDG) in lymph node (LN) staging in non-small cell lung cancer (NSCLC) has been shown in numerous papers. However, few studies have assessed its limitations. The aim of the present study is to clarify clinicopathologic factors responsible for false PET results. Methods: From July 2000 through December 2001, 71 NSCLC patients underwent both FDG PET and surgical intervention at the National Cancer Center Hospital Fast, Chiba. Clinical records, computed tomographic (CT) scan findings, PET findings, and histologic findings were retrospectively reviewed. Results: Sensitivity, specificity, accuracy in nodal staging for CT were 29, 83, and 65% and for PET were 39, 79, and 66%, respectively. There were 10 (14%) false-positive PET scans and 14 (20%) false-negative PET scans. The causative factors for false-positive PET scan were: (1) inflammatory conditions in seven patients; (2) PET mis-localization of an interlobar LN as a mediastina( LN in one patient; (3) inability to distinguish the endobronchial polypoid growth of a primary tumor from a lobar LN in one patient; (4) unknown in one patient. All false-poisitive LNs due to inflammatory conditions showed reactive lymphoid hyperplasia histologically. The causative factors for false-negative PET scan were: (1) limitation of spatial resolution of the PET scanner in 12 patients (maximum tumor focus dimensions in false-negative LNs ranging from 1 to 7.5 mm, with an average of 3.4 mm); (2) PET mis-localization of a mediastinal LN as a hilar LN in one patient; (3) weak FDG uptake by microscopic tumor foci due to necrosis with massive bleeding in a metastatic LN in one patient. Conclusions: Inflammatory conditions were most responsible for false-positive PET scans, and spatial resolution limitation of FDG PET was the causative factor of false-negative PET scans. Recognizing these factors in advance would be clinically helpful in accurate nodal staging with FDG PET. (C) 2004 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:235 / 242
页数:8
相关论文
共 34 条
[1]   Survival of patients with resected N2 non-small-cell lung cancer: Evidence for a subclassification and implications [J].
Andre, F ;
Grunenwald, D ;
Pignon, JP ;
Dujon, A ;
Pujol, JL ;
Brichon, PY ;
Brouchet, L ;
Quoix, E ;
Westeel, V ;
Le Chevalier, T .
JOURNAL OF CLINICAL ONCOLOGY, 2000, 18 (16) :2981-2989
[2]  
[Anonymous], 1999, HIST TYP LUNG PLEUR
[3]   Improved image interpretation with registered thoracic CT and positron emission tomography data sets [J].
Aquino, SL ;
Asmuth, JC ;
Moore, RH ;
Weise, SB ;
Fischman, AJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (04) :939-944
[4]   Impact of computed tomography-positron emission tomography fusion in staging patients with thoracic malignancies [J].
D'Amico, TA ;
Wong, TZ ;
Harpole, DH ;
Brown, SD ;
Coleman, RE .
ANNALS OF THORACIC SURGERY, 2002, 74 (01) :160-163
[5]   DIAGNOSTIC EFFICACY OF PET-FDG IMAGING IN SOLITARY PULMONARY NODULES - POTENTIAL ROLE IN EVALUATION AND MANAGEMENT [J].
DEWAN, NA ;
GUPTA, NC ;
REDEPENNING, LS ;
PHALEN, JJ ;
FRICK, MP .
CHEST, 1993, 104 (04) :997-1002
[6]   Metastases from non-small cell lung cancer: Mediastinal staging in the 1990s - Meta-analytic comparison of PET and CT [J].
Dwamena, BA ;
Sonnad, SS ;
Angobaldo, JO ;
Wahl, RL .
RADIOLOGY, 1999, 213 (02) :530-536
[7]  
GALLAGHER BM, 1978, J NUCL MED, V19, P1154
[8]   Test performance of positron emission tomography and computed tomography for mediastinal staging in patients with non-small-cell lung cancer - A meta-analysis [J].
Gould, MK ;
Kuschner, WG ;
Rydzak, CE ;
Maclean, CC ;
Demas, AN ;
Shigemitsu, H ;
Chan, JK ;
Owens, DK .
ANNALS OF INTERNAL MEDICINE, 2003, 139 (11) :879-892
[9]   BRONCHOGENIC-CARCINOMA METASTATIC TO NORMAL-SIZED LYMPH-NODES - FREQUENCY AND SIGNIFICANCE [J].
GROSS, BH ;
GLAZER, GM ;
ORRINGER, MB ;
SPIZARNY, DL ;
FLINT, A .
RADIOLOGY, 1988, 166 (01) :71-74
[10]   Mediastinal lymph node sampling following positron emission tomography with fluorodeoxyglucose imaging in lung cancer staging [J].
Gupta, NC ;
Tamim, WJ ;
Graeber, GG ;
Bishop, HA ;
Hobbs, GR .
CHEST, 2001, 120 (02) :521-527