Spectral simulation methodology for calibration transfer of near-infrared spectra

被引:53
作者
Sulub, Yusuf
Small, Gary W.
机构
[1] Univ Iowa, Dept Chem, Iowa City, IA 52242 USA
[2] Univ Iowa, Opt Sci & Technol Ctr, Iowa City, IA 52242 USA
关键词
simulation; near-infrared spectroscopy; calibration transfer; partial least squares; PLS; glucose;
D O I
10.1366/000370207780466280
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 [仪器科学与技术]; 080401 [精密仪器及机械]; 081102 [检测技术与自动化装置];
摘要
A spectrum simulation method is described for use in the development and transfer of multivariate calibration models from near-infrared spectra. By use of previously measured molar absorptivities and solvent displacement factors, synthetic calibration spectra are computed using only background spectra collected with the spectrometer for which a calibration model is desired. The resulting synthetic calibration set is used with partial least squares regression to form the calibration model. This methodology is demonstrated for use in the analysis of physiological levels of glucose (1-30 mM) in an aqueous matrix containing variable levels of alanine, ascorbate, lactate, urea, and triacetin. Experimentally measured data from two different Fourier transform spectrometers with different noise levels and stabilities are used to evaluate the simulation method. With the more stable instrument (A), well-performing calibration models are obtained, producing a standard error of prediction (SEP) of 0.70 mM. With the less stable instrument (B), the calibration based solely on synthetic spectra is less successful, producing an SEP value of 1.58 mM. For cases in which the synthetic spectra do not describe enough spectral variance, an augmentation protocol is evaluated in which the synthetic calibration spectra are augmented with the spectra of a small number of experimentally measured calibration samples. For instruments A and B, respectively, augmentation with measured spectra of nine samples lowers the SEP values to 0.64 and 0.85 mM.
引用
收藏
页码:406 / 413
页数:8
相关论文
共 25 条
[1]
Molar absorptivities of glucose and other biological molecules in aqueous solutions over the first overtone and combination regions of the near-infrared spectrum [J].
Amerov, AK ;
Chen, J ;
Arnold, MA .
APPLIED SPECTROSCOPY, 2004, 58 (10) :1195-1204
[2]
DETERMINATION OF PHYSIOLOGICAL LEVELS OF GLUCOSE IN AN AQUEOUS MATRIX WITH DIGITALLY FILTERED FOURIER-TRANSFORM NEAR-INFRARED SPECTRA [J].
ARNOLD, MA ;
SMALL, GW .
ANALYTICAL CHEMISTRY, 1990, 62 (14) :1457-1464
[3]
An enhanced algorithm for linear multivariate calibration [J].
Berger, AJ ;
Koo, TW ;
Itzkan, I ;
Feld, MS .
ANALYTICAL CHEMISTRY, 1998, 70 (03) :623-627
[4]
Content uniformity and tablet hardness testing of intact pharmaceutical tablets by near infrared spectroscopy -: A contribution to process analytical technologies [J].
Blanco, M ;
Alcalá, M .
ANALYTICA CHIMICA ACTA, 2006, 557 (1-2) :353-359
[5]
THE INFLUENCE OF DATA PREPROCESSING ON THE ROBUSTNESS AND PARSIMONY OF MULTIVARIATE CALIBRATION MODELS [J].
DENOORD, OE .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1994, 23 (01) :65-70
[6]
Evaluation of pretreatment strategies for near-infrared spectroscopy calibration development of unground and ground compound feedingstuffs [J].
Fernández-Cabanás, VM ;
Garrido-Varo, A ;
Pérez-Marín, D ;
Dardenne, P .
APPLIED SPECTROSCOPY, 2006, 60 (01) :17-23
[7]
A STATISTICAL VIEW OF SOME CHEMOMETRICS REGRESSION TOOLS [J].
FRANK, IE ;
FRIEDMAN, JH .
TECHNOMETRICS, 1993, 35 (02) :109-135
[8]
New prediction-augmented classical least-squares (PACLS) methods: Application to unmodeled interferents [J].
Haaland, DM ;
Melgaard, DK .
APPLIED SPECTROSCOPY, 2000, 54 (09) :1303-1312
[9]
New classical least-squares/partial least-squares hybrid algorithm for spectral analyses [J].
Haaland, DM ;
Melgaard, DK .
APPLIED SPECTROSCOPY, 2001, 55 (01) :1-8
[10]
PARTIAL LEAST-SQUARES METHODS FOR SPECTRAL ANALYSES .1. RELATION TO OTHER QUANTITATIVE CALIBRATION METHODS AND THE EXTRACTION OF QUALITATIVE INFORMATION [J].
HAALAND, DM ;
THOMAS, EV .
ANALYTICAL CHEMISTRY, 1988, 60 (11) :1193-1202