Electrode Design for High Frequency Block: Effect of Bipolar Separation on Block Thresholds and the Onset Response

被引:12
作者
Ackermann, D. Michael, Jr. [1 ,2 ]
Foldes, Emily L. [2 ]
Bhadra, Niloy [2 ]
Kilgore, Kevin L. [2 ,3 ,4 ]
机构
[1] Cleveland FES Ctr, Hamman 601,2500 MetroHealth Dr, Cleveland, OH 44109 USA
[2] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44109 USA
[3] Metrohlth Med Ctr, Dept Orthopaed, Cleveland, OH 44109 USA
[4] Louis Stokes Veterans Affairs Med Ctr, Cleveland, OH 44109 USA
来源
2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20 | 2009年
关键词
ELECTRICAL-CONDUCTION BLOCK; PUDENDAL NERVE; STIMULATION;
D O I
10.1109/IEMBS.2009.5332738
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The delivery of high frequency alternating currents (HFAC) to peripheral nerves has been shown to produce a rapid and reversible nerve conduction block at the site of the electrode, and holds therapeutic promise for diseases associated with undesired or pathological neural activity. It has been known since 1939 that the configuration of an electrode used for nerve block can impact the quality of the block, but to date no formal study of the impact of electrode design on high frequency nerve block has been performed. Using a mammalian small animal model, it is demonstrated that the contact separation distance for a bipolar nerve cuff electrode can impact two important factors related to high frequency nerve block: the amplitude of HFAC required to block the nerve (block threshold), and the degree to which the transient "onset response" which always occurs when HFAC is first applied to peripheral nerves, is present. This study suggests that a bipolar electrode with a separation distance of 1.0 mm minimizes current delivery while producing high frequency block with a minimal onset response in the rat sciatic nerve.
引用
收藏
页码:654 / +
页数:2
相关论文
共 16 条
[1]   ORDERLY STIMULATION OF SKELETAL-MUSCLE MOTOR UNITS WITH TRIPOLAR NERVE CUFF ELECTRODE [J].
BARATTA, R ;
ICHIE, M ;
HWANG, SK ;
SOLOMONOW, M .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (08) :836-843
[2]   High-frequency electrical conduction block of mammalian peripheral motor nerve [J].
Bhadra, N ;
Kilgore, KL .
MUSCLE & NERVE, 2005, 32 (06) :782-790
[3]   High frequency electrical conduction block of the pudendal nerve [J].
Bhadra, Narendra ;
Bhadra, Niloy ;
Kilgore, Kevin ;
Gustafson, Kenneth J. .
JOURNAL OF NEURAL ENGINEERING, 2006, 3 (02) :180-186
[4]  
Bhadra N, 2007, J COMPUT NEUROSCI, V22, P313, DOI [10.1007/s10827-006-0015-5, 10.1007/S10827-006-0015-5]
[5]   Bladder voiding by combined high frequency electrical pudendal nerve block and sacral root stimulation [J].
Boger, Adam ;
Bhadra, Narendra ;
Gustafson, Kenneth J. .
NEUROUROLOGY AND URODYNAMICS, 2008, 27 (05) :435-439
[6]  
BOWMAN BR, 1986, APPL NEUROPHYSIOL, V49, P121
[7]  
Cattell M, 1935, J PHYSIOL-LONDON, V83, P407, DOI 10.1113/jphysiol.1935.sp003238
[8]  
CHANGFENG T, 2005, NEURAL SYSTEMS REHAB, V13, P415
[9]   Nerve conduction block utilising high-frequency alternating current [J].
Kilgore, KL ;
Bhadra, N .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2004, 42 (03) :394-406
[10]  
LOPEZ B, 2004, NEUROSURGERY, V54