Ten years measuring PCDDs/PCDFs in ambient air in Catalonia (Spain)

被引:61
作者
Abad, Esteban
Martinez, Karell
Gustems, Lluis
Gomez, Rafael
Guinart, Xavier
Hernandez, Isabel
Rivera, Josep
机构
[1] CSIC, IIQAB, Dept Ecotechnol, Mass Spectrometry Lab,Dioxin Lab, ES-08034 Barcelona, Spain
[2] Dept Medi Ambient Generalitat Catalunya, Barcelona 08029, Spain
关键词
PCDD/Fs; dioxins; furans; ambient air; monitoring; survey;
D O I
10.1016/j.chemosphere.2006.05.083
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This work summarizes the results of a ten year surveillance programme on PCDD/F in ambient air carried out in Catalonia (Spain). The study has been conducted by the Dioxin Laboratory of Spanish Council for Scientific Research (CSIC) in collaboration with the Environment Department of the Catalonian Government. 175 samples have been collected throughout Catalonia from 1994 to 2004. Different sampling locations classified as industrial, traffic, urban, suburban and rural sites have been monitored in order to find the most contaminated zones as well as the ones with expected background concentrations. The highest concentrations found in this study were determined at the industrial locations. Concentrations ranging from 5 to 1196 fg I-TEQ/m(3), with a mean value of 140 fg I-TEQ/m(3) and from 10 to 357 fg I-TEQ/m(3), with a mean value of 72 fg I-TEQ/m(3) were determined in industrial and traffic sampling points, respectively. In contrast, the lowest concentrations were found in rural stations, ranging 33 from 5 to 45 fg I-TEQ/m(3), with a mean value of 28 fg I-TEQ/m(3). The PCDD/F concentration trend in Catalonian ambient air shown a clear drop of the median values occurred during the study sampling period. A decline of about 70% was observed from 1997-1998 to 2003-2004. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1709 / 1714
页数:6
相关论文
共 24 条
[1]   Application of DB-5ms gas chromatography column for the complete assignment of 2,3,7,8-substituted polychlorodibenzo-p-dioxins and polychlorodibenzofurans in samples from municipal waste incinerator emissions [J].
Abad, E ;
Caixach, J ;
Rivera, J .
JOURNAL OF CHROMATOGRAPHY A, 1997, 786 (01) :125-134
[2]   PCDD/PCDF from emission sources and ambient air in northeast Spain [J].
Abad, E ;
Caixach, J ;
Rivera, J .
CHEMOSPHERE, 1997, 35 (03) :453-463
[3]   Evaluation of a new automated cleanup system for the analysis of polychlorinated dibenzo-p-dioxins and dibenzofurans in environmental samples [J].
Abad, E ;
Sauló, J ;
Caixach, J ;
Rivera, J .
JOURNAL OF CHROMATOGRAPHY A, 2000, 893 (02) :383-391
[4]   Temporal trends of PCDDs/PCDFs in ambient air in Catalonia (Spain) [J].
Abad, E ;
Caixach, J ;
Rivera, J ;
Gustems, L ;
Massagué, G ;
Puig, O .
SCIENCE OF THE TOTAL ENVIRONMENT, 2004, 334 :279-285
[5]   A congener-specific PCDD/F emissions inventory for the UK: do current estimates account for the measured atmospheric burden? [J].
Alcock, RE ;
Sweetman, AJ ;
Jones, KC .
CHEMOSPHERE, 2001, 43 (02) :183-194
[6]   Polychlorinated dibenzo-p-dioxins and dibenzofurans in the remote North Atlantic marine atmosphere [J].
Baker, JI ;
Hites, RA .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1999, 33 (01) :14-20
[7]   AMBIENT AIR DIOXIN MEASUREMENT IN THE NETHERLANDS [J].
BOLT, A ;
JONG, APJM .
CHEMOSPHERE, 1993, 27 (1-3) :73-81
[8]   Air and soil dioxin levels at three sites in Italy in proximity to MSW incineration plants [J].
Caserini, S ;
Cernuschi, S ;
Giugliano, M ;
Grosso, M ;
Lonati, G ;
Mattaini, P .
CHEMOSPHERE, 2004, 54 (09) :1279-1287
[9]   Size distribution of particle-bound polychlorinated dibenzo-p-dioxins and dibenzofurans in the ambient air of a municipal incinerator [J].
Chao, MR ;
Hu, CW ;
Ma, HW ;
Chang-Chien, GP ;
Lee, WJ ;
Chang, LW ;
Wu, KY .
ATMOSPHERIC ENVIRONMENT, 2003, 37 (35) :4945-4954
[10]   Characterizing polychlorinated dibenzo-p-dioxins and dibenzofurans in the surrounding environment and workplace of a secondary aluminum smelter [J].
Chen, SJ ;
Lee, WS ;
Chang-Chien, GP ;
Wang, LC ;
Lee, WJ ;
Kao, JH ;
Hu, MT .
ATMOSPHERIC ENVIRONMENT, 2004, 38 (22) :3729-3732