Long-Term Clinical and Economic Analysis of the Endeavor Drug-Eluting Stent Versus the Driver Bare-Metal Stent 4-Year Results From the ENDEAVOR II Trial (Randomized Controlled Trial to Evaluate the Safety and Efficacy of the Medtronic AVE ABT-578 Eluting Driver Coronary Stent in De Novo Native Coronary Artery Lesions)

被引:26
作者
Eisenstein, Eric L. [1 ]
Wijns, William [2 ]
Fajadet, Jean [3 ]
Mauri, Laura [4 ]
Edwards, Rex [1 ]
Cowper, Patricia A. [1 ]
Kong, David F. [1 ]
Anstrom, Kevin J. [1 ]
机构
[1] Duke Clin Res Inst, Durham, NC 27705 USA
[2] Ctr Cardiovasc, Aalst, Belgium
[3] Clin Pasteur, Toulouse, France
[4] Harvard Univ, Brigham & Womens Hosp, Sch Med, Harvard Clin Res Inst, Boston, MA 02115 USA
关键词
drug-eluting stents; bare-metal stents; coronary disease; revascularization; cost analysis; TAXUS-IV TRIAL; COST-EFFECTIVENESS; RESTENOSIS; OUTCOMES; REVASCULARIZATION;
D O I
10.1016/j.jcin.2009.10.011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives This study was designed to evaluate long-term clinical and economic outcomes for subjects receiving Endeavor drug-eluting versus Driver bare-metal stents (both Medtronic CardioVascular, Santa Rosa, California). Background Early studies found that the drug-eluting stent (DES) was a clinically and economically attractive alternative to the bare-metal stent; however, associations between DES and very late stent thrombosis suggest that longer follow-up is required. Methods We used clinical, resource use and follow-up data from 1,197 subjects randomized to receive Endeavor (n = 598) versus Driver (n = 599) stents in ENDEAVOR II (Randomized Controlled Trial to Evaluate the Safety and Efficacy of the Medtronic AVE ABT-578 Eluting Driver Coronary Stent in De Novo Native Coronary Artery Lesions) study with Medicare cost weights and quality of life adjustments applied from secondary sources. We compared differences through 4-year follow-up (1,440 days). Results Patients in both treatment groups had similar baseline characteristics. The use of Endeavor versus Driver reduced 4-year target vessel revascularization rates per 100 subjects (10.4 vs. 21.5; difference: -11.1; 95% confidence interval [CI]: -16.0 to -6.1; p < 0.001), with no difference in the rates per 100 subjects of death (5.0 vs. 5.2; difference: -0.2; 95% CI: -2.7 to 2.4; p = 0.90) or nonfatal myocardial infarction (3.2 vs. 4.4; difference: -1.2; 95% CI: -3.4 to 1.0; p = 0.29). After discounting at a 3% annual rate, there were no differences in quality-adjusted survival days (1,093 vs. 1,090; difference: 3; 95% CI: -13 to 19; p = 0.69) and total medical costs ($21,483 vs. $21,680; difference: -$198; 95% CI: -$1,608 to $1,207; p = 0.78). Conclusions The use of Endeavor versus Driver was associated with a significant reduction in target vessel revascularization through 4-year follow-up with no difference in death, nonfatal myocardial infarction, quality-adjusted survival, or total medical costs. These results are comparable to those for other studies evaluating drug-eluting versus bare-metal stents. (Randomized Controlled Trial to Evaluate the Safety and Efficacy of the Medtronic AVE ABT-578 Eluting Driver Coronary Stent in De Novo Native Coronary Artery Lesions [ENDEAVOR II]; NCT00614848) Q Am Coll Cardiol Intv 2009;2: 1178-87) (C) 2009 by the American College of Cardiology Foundation
引用
收藏
页码:1178 / 1187
页数:10
相关论文
共 29 条
[1]  
[Anonymous], 1996, Cost-effectiveness in health and medicine
[2]   Cost effectiveness of paclitaxel-eluting stents for patients undergoing percutaneous coronary revascularization - Results from the TAXUS-IV trial [J].
Bakhai, Ameet ;
Stone, Gregg W. ;
Mahoney, Elizabeth ;
Lavelle, Tara A. ;
Shi, Chunxue ;
Berezin, Ronna H. ;
Lahue, Betsy J. ;
Clark, Mary Ann ;
Lacey, Michael J. ;
Russell, Mary E. ;
Ellis, Stephen G. ;
Hermiller, James B. ;
Cox, David A. ;
Cohen, David J. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (02) :253-261
[3]   Estimating medical costs with censored data [J].
Bang, H ;
Tsiatis, AA .
BIOMETRIKA, 2000, 87 (02) :329-343
[4]  
Barber JA, 2000, STAT MED, V19, P3219, DOI 10.1002/1097-0258(20001215)19:23<3219::AID-SIM623>3.0.CO
[5]  
2-P
[6]   Cost-effectiveness of sirolimus-eluting stents for treatment of complex coronary stenoses - Results from the sirolimus-eluting balloon expandable stent in the treatment of patients with de novo native coronary artery lesions (SIRIUS) trial [J].
Cohen, DJ ;
Bakhai, A ;
Shi, CX ;
Githiora, L ;
Lavelle, T ;
Berezin, RH ;
Leon, MB ;
Moses, JW ;
Carrozza, JP ;
Zidar, JP ;
Kuntz, RE .
CIRCULATION, 2004, 110 (05) :508-514
[7]  
Collett S., 1999, COMPUTERWORLD 33, P8
[8]   Beyond restenosis - Five-year clinical outcomes from second-generation coronary stent trials [J].
Cutlip, DE ;
Chhabra, AG ;
Baim, DS ;
Chauhan, MS ;
Marulkar, S ;
Massaro, J ;
Bakhai, A ;
Cohen, DJ ;
Kuntz, RE ;
Ho, KKL .
CIRCULATION, 2004, 110 (10) :1226-1230
[9]   Clinical end points in coronary stent trials - A case for standardized definitions [J].
Cutlip, Donald E. ;
Windecker, Stephan ;
Mehran, Roxana ;
Boam, Ashley ;
Cohen, David J. ;
van Es, Gerrit-Anne ;
Steg, P. Gabriel ;
Morel, Marie-angele ;
Mauri, Laura ;
Vranckx, Pascal ;
McFadden, Eugene ;
Lansky, Alexandra ;
Hamon, Martial ;
Krucoff, Mitchell W. ;
Serruys, Patrick W. .
CIRCULATION, 2007, 115 (17) :2344-2351
[10]  
*ENDEAVOR 2 INV, 2008, ENDEAVOR 2 STUD CLIN, P87