SAW sensors for the room-temperature measurement of CO2 and relative humidity

被引:60
作者
Hoyt, AE
Ricco, AJ
Bartholomew, JW
Osbourn, GC
机构
[1] Sandia Natl Labs, Dept Vis Sci, Albuquerque, NM 87185 USA
[2] Sandia Natl Labs, Microsensor R&D Dept, Albuquerque, NM 87185 USA
关键词
D O I
10.1021/ac971095z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A pair of polymer-coated 97-MHz SAW delay lines allows simultaneous determination of the concentrations of CO2 and H2O in the gas phase at room temperature, The SAW response of a 370-nm-thick, CO2-permeable polyimide prepared from hexafluoroisopropylidene diphthtalic anhydride and 2,4,5,6-tetramethylphenylenediamine is rapid and reversible for CO2 concentrations from 0.03 to 97% of 1 atm in a pure nitrogen carrier gas stream, but with significant interference from humidity. A 40-nm-thick layer of the hydrophilic material poly(N-vinylpyrrolidone) (PNVP) responds primarily to humidity; 10-60% relative humidity has been examined for a wide range or accompanying CO2 concentrations, Using visually empirical region-of-influence pattern recognition, the optimum two-sensor pair was selected from several possibilities. The effects of noise and gradual film sensitivity degradation ("aging") upon the accuracy of determining CO2 and H2O concentrations were examined: we find that the polyimide-and Pi-coated SAW device pair allows robust quantitation of H2O over the entire concentration range examined, but robust quantitation of CO2 is possible only at low humidity.
引用
收藏
页码:2137 / 2145
页数:9
相关论文
共 24 条
[1]  
Ballantine D.S., 1997, ACOUSTIC WAVE SENSOR
[2]   Molecular design of intercalation based sensors .2. Sensing of carbon dioxide in functionalized thin films of copper octanediylbis(phosphonate) [J].
Brousseau, LC ;
Aurentz, DJ ;
Benesi, AJ ;
Mallouk, TE .
ANALYTICAL CHEMISTRY, 1997, 69 (04) :688-694
[3]   CHARACTERIZATION AND GAS-PERMEABILITY OF A 3-COMPONENT POLYIMIDE SERIES [J].
CHUN, BW ;
ISHIZU, C ;
ITATANI, H ;
HARAYA, K ;
SHINDO, Y .
JOURNAL OF POLYMER SCIENCE PART B-POLYMER PHYSICS, 1994, 32 (06) :1009-1016
[4]  
Harris F. W., 1989, HighPerform. Polym, V1, P3, DOI DOI 10.1177/095400838900100101
[5]   EFFECTS OF DIAMINE MONOMER STRUCTURE ON THE GAS-PERMEABILITY OF POLYIMIDES .1. BRIDGED DIAMINES [J].
LANGSAM, M ;
BURGOYNE, WF .
JOURNAL OF POLYMER SCIENCE PART A-POLYMER CHEMISTRY, 1993, 31 (04) :909-921
[6]  
LIPSETT MJ, 1994, PATTYS IND HYGIENE T, V2, pF4552
[7]   ISOTHERMAL MEASUREMENTS AND THERMAL-DESORPTION OF ORGANIC VAPORS USING SAW DEVICES [J].
MARTIN, SJ ;
RICCO, AJ ;
GINLEY, DS ;
ZIPPERIAN, TE .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1987, 34 (02) :142-147
[8]   DYNAMICS AND RESPONSE OF POLYMER-COATED SURFACE-ACOUSTIC-WAVE DEVICES - EFFECT OF VISCOELASTIC PROPERTIES AND FILM RESONANCE [J].
MARTIN, SJ ;
FRYE, GC ;
SENTURIA, SD .
ANALYTICAL CHEMISTRY, 1994, 66 (14) :2201-2219
[9]   GAS PERMEATION OF AROMATIC POLYIMIDES .2. INFLUENCE OF CHEMICAL-STRUCTURE [J].
MATSUMOTO, K ;
XU, P .
JOURNAL OF MEMBRANE SCIENCE, 1993, 81 (1-2) :23-30
[10]   A SAW GAS SENSOR FOR CARBON-DIOXIDE AND WATER - PRELIMINARY EXPERIMENTS [J].
NIEUWENHUIZEN, MS ;
NEDERLOF, AJ .
SENSORS AND ACTUATORS B-CHEMICAL, 1990, 2 (02) :97-101