2003 Hap Paul Award paper of the international society for technology in arthroplasty

被引:141
作者
Banks, SA
Hodge, WA
机构
[1] Univ Florida, Dept Mech & Aerosp Engn, Gainesville, FL 32611 USA
[2] Biomot Fdn, W Palm Beach, FL USA
[3] Palm Beach Orthopaed Inst, W Palm Beach, FL USA
关键词
knee arthroplasty; kinematics; fluoroscopy; implant design; gait; stair climbing;
D O I
10.1016/j.arth.2004.04.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Knee arthroplasty implants are designed with features that provide varying articular constraint over the range of flexion such that the pattern of knee motion may also vary. Because the motions of total knee implants have a direct influence on patient function and device longevity, it is important to understand how knee implants based on a variety of design philosophies perform in vivo. Fifty-nine knees in patients with 5 designs of implants were studied with fluoro-scopic imaging during gait and stair-climbing activities. Many knees showed significantly different kinematics between the gait and stair activities, as well as differences from knees having other implant designs. The measured motions were consistent with the intrinsic constraint provided by the implant components and the variation in constraint over the flexion range. Key Avords: knee arthroplasty, kinematics, fluoroscopy, implant design, gait, stair climbing. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:809 / 816
页数:8
相关论文
共 20 条
[1]
THE INFLUENCE OF TOTAL KNEE-REPLACEMENT DESIGN ON WALKING AND STAIR-CLIMBING [J].
ANDRIACCHI, TP ;
GALANTE, JO ;
FERMIER, RW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (09) :1328-1335
[2]
Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties [J].
Banks, S ;
Bellemans, J ;
Nozaki, H ;
Whiteside, LA ;
Harman, M ;
Hodge, WA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (410) :131-138
[3]
In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties [J].
Banks, SA ;
Markovich, GD ;
Hodge, WA .
JOURNAL OF ARTHROPLASTY, 1997, 12 (03) :297-304
[4]
Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy [J].
Banks, SA ;
Hodge, WA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (06) :638-649
[5]
Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty - Influence of posterior condylar offset [J].
Bellemans, J ;
Banks, S ;
Victor, J ;
Vandenneucker, H ;
Moemans, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B :50-53
[6]
Effect of stair descent loading on ultra-high molecular weight polyethylene wear in a force-controlled knee simulator [J].
Benson, LC ;
DesJardins, JD ;
Harman, MK ;
LaBerge, M .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2002, 216 (H6) :409-418
[7]
In vivo determination of posterior femoral rollback for subjects having a NexGen posterior cruciate-retaining total knee arthroplasty [J].
Bertin, KC ;
Komistek, RD ;
Dennis, DA ;
Hoff, WA ;
Anderson, DT ;
Langer, T .
JOURNAL OF ARTHROPLASTY, 2002, 17 (08) :1040-1048
[8]
BLUNN GW, 1991, CLIN ORTHOP RELAT R, P253
[9]
Intraoperative measurement of knee kinematics in reconstruction of the anterior cruciate ligament [J].
Bull, AMJ ;
Earnshaw, PH ;
Smith, A ;
Katchburian, MV ;
Hassan, ANA ;
Amis, AA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (07) :1075-1081
[10]
Dennis DA, 1996, CLIN ORTHOP RELAT R, P107