Doppler sonography of the portal vein and hepatic artery: Measurement of a prandial effect in healthy subjects

被引:22
作者
Fisher, AJ [1 ]
Paulson, EK [1 ]
Kliewer, MA [1 ]
DeLong, DM [1 ]
Nelson, RC [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
关键词
blood; flow dynamics; hepatic arteries; portal vein; ultrasound; (US); Doppler studies;
D O I
10.1148/radiology.207.3.9609894
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine if the prandial effect outweighs variability in the measurement of portal venous blood flow and hepatic arterial resistive index. MATERIALS AND METHODS: Fourteen healthy adult volunteers fasted overnight. For eight of the subjects, two sonographers performed three determinants of portal venous blood flow and hepatic arterial resistive index before and 30 minutes after a liquid meal (5 mg per kilogram of body weight). In the remaining six volunteers, determinants were made at the same time intervals but without a meal. The sonographers were blinded to on-screen measurements and the subject's prandial status. RESULTS: For subjects examined after the meal by sonographers A and B, respectively, portal venous blood flow increased from 144.2 to 201.7 mL/min and from 209.2 to 331.9 mL/min and hepatic arterial resistive index increased from 0.70 to 0.77 and from 0.67 to 0.78. After repeated-measures analysis of variance, ingestion of a meal was estimated to increase portal venous blood flow by 96.3 mL/min (P < .001)-a change in sonographers could affect the measurement by 76.7 mL/min (P < .001)-and to increase hepatic arterial resistive index by 0.089 (P < .001)-a change in sonographers did not affect the measurement (P > .1). CONCLUSION: The prandial effect on portal venous blood flow is only marginally greater than the interobserver variation in the measurement. Hepatic arterial resistive index also increases after a meal, but interobserver differences between sonographers are minimal; therefore, it is a more robust measurement.
引用
收藏
页码:711 / 715
页数:5
相关论文
共 23 条
[1]  
ALVAREZ D, 1994, HEPATOLOGY, V20, P1198, DOI 10.1002/hep.1840200515
[2]   PULSUS TARDUS - ITS CAUSE AND POTENTIAL LIMITATIONS IN DETECTION OF ARTERIAL-STENOSIS [J].
BUDE, RO ;
RUBIN, JM ;
PLATT, JF ;
FECHNER, KP ;
ADLER, RS .
RADIOLOGY, 1994, 190 (03) :779-784
[3]   DOPPLER FLOWMETRY AND PORTAL-HYPERTENSION [J].
BURNS, P ;
TAYLOR, K ;
BLEI, AT .
GASTROENTEROLOGY, 1987, 92 (03) :824-826
[4]  
BURNS PN, 1985, RADIOL CLIN N AM, V23, P641
[5]   HEPATIC-ARTERY STENOSIS AND THROMBOSIS IN TRANSPLANT RECIPIENTS - DOPPLER DIAGNOSIS WITH RESISTIVE INDEX AND SYSTOLIC ACCELERATION TIME [J].
DODD, GD ;
MEMEL, DS ;
ZAJKO, AB ;
BARON, RL ;
SANTAGUIDA, LA .
RADIOLOGY, 1994, 192 (03) :657-661
[6]   EFFECT OF MEAL ON PORTAL HEMODYNAMICS IN HEALTHY HUMANS AND IN PATIENTS WITH CHRONIC LIVER-DISEASE [J].
GAIANI, S ;
BOLONDI, L ;
LIBASSI, S ;
SANTI, V ;
ZIRONI, G ;
BARBARA, L .
HEPATOLOGY, 1989, 9 (06) :815-819
[8]   THE RESPONSE OF THE PORTAL-VEIN TO AN ORAL GLUCOSE-LOAD [J].
GOLDBERG, REA ;
RADA, C ;
KNELSON, M ;
HAAGA, J ;
MINKIN, S .
JOURNAL OF CLINICAL ULTRASOUND, 1990, 18 (09) :691-695
[9]   NORMAL RENAL-ARTERY SPECTRAL DOPPLER WAVE-FORM - A CLOSER LOOK [J].
HALPERN, EJ ;
DEANE, CR ;
NEEDLEMAN, L ;
MERTON, DA ;
EAST, SA .
RADIOLOGY, 1995, 196 (03) :667-673
[10]   Echo-doppler measurements of portal vein and superior mesenteric artery blood flow in humans: Inter- and intra-observer short-term reproducibility [J].
Iwao, T ;
Toyonaga, A ;
Shigemori, H ;
Oho, K ;
Sumino, M ;
Sato, M ;
Tanikawa, K .
JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 1996, 11 (01) :40-46