Hand and wrist imaging using a low-field dedicated MRI system

被引:9
作者
Bonel, H [1 ]
Frick, A [1 ]
Sittek, H [1 ]
Heuck, A [1 ]
Steinborn, M [1 ]
Baumeister, RGH [1 ]
Reiser, M [1 ]
机构
[1] UNIV MUNICH,KLINIKUM GROSSHADERN,PLAST HAND MIKROCHIRURG CHIRURG KLIN & POLIKLIN,D-81377 MUNICH,GERMANY
来源
RADIOLOGE | 1997年 / 37卷 / 10期
关键词
MRI; low-field; MRI dedicated; diagnostic imaging; hand; wrist;
D O I
10.1007/s001170050283
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Purpose of this study was to evaluate the diagnostic value of a low field dedicated MRI system in hand and wrist imaging. All 308 exams of the hand and wrist, that were performed on a low-field dedicated MRI system (Artoscan, Esaote Biomedica, Italy) in our institution in 1996, and high-field MRI exams performed in addition as part of the diagnostic work-up, were evaluated and correlated to final operative (n = 64) and histologic (n = 12) reports. 90 % of all low-field MRI scans stated a diagnosis according to clinical suspicion. In 62 % the clinical ques question was answered, and in 26 % additional pathologies were identified. An MR-diagnosis completely different from the clinical suspicion was stated in 2 %. High field exams contributed additional information in 6 of 36 patients. In 3 patients a tumor was not shown completely in the limited field-of-view of the dedicated low-field MRI-system. Frequency-selective fat-suppression pulse sequences and a better spatial resolution were the reasons for the additional information obtained in the other three patients. Low-field dedicated MR-imaging is a valuable method in the extensive work-up of the hand and wrist. Osseous, ligamentous and tendinous pathologies are well depicted. large or infiltrative tumors should be referred to a high-field system.
引用
收藏
页码:785 / 793
页数:9
相关论文
共 12 条
[1]
SUBTRACTION TECHNIQUE FOR CONTRAST-ENHANCED MR IMAGES OF MUSCULOSKELETAL TUMORS [J].
HANNA, SL ;
LANGSTON, JW ;
GRONEMEYER, SA ;
FLETCHER, BD .
MAGNETIC RESONANCE IMAGING, 1990, 8 (03) :213-215
[2]
MAGNETIZATION-TRANSFER CONTRAST MRI OF MUSCULOSKELETAL NEOPLASMS [J].
LI, KCP ;
HOPKINS, KL ;
MOORE, SG ;
LOH, NN ;
BERGMAN, G ;
PIKE, GB ;
GLOVER, GH .
SKELETAL RADIOLOGY, 1995, 24 (01) :21-25
[3]
MR imaging of musculoskeletal tumors and tumor mimickers with intravenous gadolinium: Experience with 242 patients [J].
May, DA ;
Good, RB ;
Smith, DK ;
Parsons, TW .
SKELETAL RADIOLOGY, 1997, 26 (01) :2-15
[4]
MAGNETIC-RESONANCE-IMAGING OF BENIGN SOFT-TISSUE MASSES OF THE HAND AND WRIST [J].
PEH, WCG ;
TRUONG, NP ;
TOTTY, WG ;
GILULA, LA .
CLINICAL RADIOLOGY, 1995, 50 (08) :519-525
[5]
GADOLINIUM-DTPA IN RHEUMATOID-ARTHRITIS AND RELATED DISEASES - FIRST RESULTS WITH DYNAMIC MAGNETIC-RESONANCE IMAGING [J].
REISER, MF ;
BONGARTZ, GP ;
ERLEMANN, R ;
SCHNEIDER, M ;
PAULY, T ;
SITTEK, H ;
PETERS, PE .
SKELETAL RADIOLOGY, 1989, 18 (08) :591-597
[6]
Rettig M E, 1995, Magn Reson Imaging Clin N Am, V3, P361
[7]
MR-IMAGING OF ANATOMY AND TEARS OF WRIST LIGAMENTS [J].
ROMINGER, MB ;
BERNREUTER, WK ;
KENNEY, PJ ;
LEE, DH .
RADIOGRAPHICS, 1993, 13 (06) :1233-1246
[8]
NIR imaging of the foot: Utility of complex oblique imaging planes [J].
Rubin, DA ;
Towers, JD ;
Britton, CA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (05) :1079-1084
[9]
Lesions of the triangular fibrocartilage complex: MR findings with a three-dimensional gradient-recalled-echo sequence [J].
Totterman, SMS ;
Miller, RJ ;
McCance, SE ;
Meyers, SP .
RADIOLOGY, 1996, 199 (01) :227-232
[10]
VAHLENSIECK M, 1994, SKELETAL RADIOL, V23, P535