Velocity-difference induced focusing of xanthine and purine metabolites by capillary electrophoresis using a dynamic pH junction

被引:21
作者
Britz-McKibbin, P [1 ]
Chen, DDY [1 ]
机构
[1] Univ British Columbia, Dept Chem, Vancouver, BC V6T 1Z1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
capillary electrophoresis; dynamic pH junction; velocity-difference induced focusing; xanthine analysis; purine metabolites; urine;
D O I
10.1007/BF02497482
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Velocity-difference induced focusing (V-DIF) of analytes by a dynamic pH junction represents a simple yet effective on-line preconcentration method to improve concentration sensitivity in capillary electrophoresis (CE), Differences in buffer type, pH and conductivity between sample and background electrolyte (BGE) segments of the capillary are properties used to optimize purine focusing within a multi-section electrolyte system. This method permits the injection of large volumes of sample (up to 450 nL or about 18% of capillary length), resulting in over a 50-fold improvement in sensitivity with baseline resolution. The limit of detection (S/N = 3) for xanthine is determined to less than 4,0 x 10(-8) M under optimum conditions when using UV detection. Analysis of micromolor amounts of xanthine in pooled urine is also demonstrated without sample pretreatment. A dual mechanism involving dynamic pH and isotachophoretic modes is proposed to enhance analyte focusing performance when employing buffer pH junctions based on different types of electrolyte co-ions.
引用
收藏
页码:87 / 93
页数:7
相关论文
共 52 条
[1]  
Adam T, 1999, CLIN CHEM, V45, P2086
[2]  
Adam T, 1999, ELECTROPHORESIS, V20, P564, DOI 10.1002/(SICI)1522-2683(19990301)20:3<564::AID-ELPS564>3.0.CO
[3]  
2-B
[4]   ANALYSIS OF DILUTE PEPTIDE SAMPLES BY CAPILLARY ZONE ELECTROPHORESIS [J].
AEBERSOLD, R ;
MORRISON, HD .
JOURNAL OF CHROMATOGRAPHY, 1990, 516 (01) :79-88
[5]  
Baryla NE, 2001, ELECTROPHORESIS, V22, P52, DOI 10.1002/1522-2683(200101)22:1<52::AID-ELPS52>3.3.CO
[6]  
2-Q
[7]   ISOTACHOPHORESIS SUPERIMPOSED ON CAPILLARY ZONE ELECTROPHORESIS [J].
BECKERS, JL .
JOURNAL OF CHROMATOGRAPHY, 1993, 641 (02) :363-373
[8]   On-line focusing of flavin derivatives using dynamic pH junction-sweeping capillary electrophoresis with laser-induced fluorescence detection [J].
Britz-McKibbin, P ;
Otsuka, K ;
Terabe, S .
ANALYTICAL CHEMISTRY, 2002, 74 (15) :3736-3743
[9]   Selective focusing of catecholamines and weakly acidic compounds by capillary electrophoresis using a dynamic pH junction [J].
Britz-McKibbin, P ;
Chen, DDY .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1242-1252
[10]   Velocity-difference induced focusing of nucleotides in capillary electrophoresis with a dynamic pH junction [J].
Britz-McKibbin, P ;
Bebault, GM ;
Chen, DDY .
ANALYTICAL CHEMISTRY, 2000, 72 (08) :1729-1735