Ultrasensitive investigations of biological systems by fluorescence correlation spectroscopy

被引:188
作者
Haustein, E [1 ]
Schwille, P [1 ]
机构
[1] Max Planck Inst Biophys Chem, D-37077 Gottingen, Germany
关键词
fluctuations; FCS; diffusion; membrane;
D O I
10.1016/S1046-2023(02)00306-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fluorescence correlation spectroscopy (FCS) extracts information about molecular dynamics from the tiny fluctuations that can be observed in the emission of small ensembles of fluorescent molecules in thermodynamic equilibrium. Employing a confocal setup in conjunction with highly dilute samples, the average number of fluorescent particles simultaneously within the measurement volume (similar to1 fl) is minimized. Among the multitude of chemical and physical parameters accessible by FCS are local concentrations, mobility coefficients, rate constants for association and dissociation processes, and even enzyme kinetics. As any reaction causing an alteration of the primary measurement parameters such as fluorescence brightness or mobility can be monitored, the application of this noninvasive method to unravel processes in living cells is straightforward. Due to the high spatial resolution of less than 0.5 mum, selective measurements in cellular compartments, e.g., to probe receptor-ligand interactions on cell membranes, are feasible. Moreover, the observation of local molecular dynamics provides access to environmental parameters such as local oxygen concentrations, pH, or viscosity. Thus, this versatile technique is of particular attractiveness for researchers striving for quantitative assessment of interactions and dynamics of small molecular quantities in biologically relevant systems. (C) 2003 Elsevier Science (USA). All rights reserved.
引用
收藏
页码:153 / 166
页数:14
相关论文
共 65 条
[11]  
Dorre K., 1997, Bioimaging, V5, P139, DOI 10.1002/1361-6374(199709)5:3<139::AID-BIO8>3.3.CO
[12]  
2-R
[13]   Highly efficient single molecule detection in microstructures [J].
Dörre, K ;
Stephan, J ;
Lapczyna, M ;
Stuke, M ;
Dunkel, H ;
Eigen, M .
JOURNAL OF BIOTECHNOLOGY, 2001, 86 (03) :225-236
[14]   SORTING SINGLE MOLECULES - APPLICATION TO DIAGNOSTICS AND EVOLUTIONARY BIOTECHNOLOGY [J].
EIGEN, M ;
RIGLER, R .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1994, 91 (13) :5740-5747
[15]   FLUORESCENCE CORRELATION SPECTROSCOPY .1. CONCEPTUAL BASIS AND THEORY [J].
ELSON, EL ;
MAGDE, D .
BIOPOLYMERS, 1974, 13 (01) :1-27
[16]   Constrained diffusion or immobile fraction on cell surfaces: A new interpretation [J].
Feder, TJ ;
BrustMascher, I ;
Slattery, JP ;
Baird, B ;
Webb, WW .
BIOPHYSICAL JOURNAL, 1996, 70 (06) :2767-2773
[17]   Fluorescence correlation spectroscopy in small cytosolic compartments depends critically on the diffusion model used [J].
Gennerich, A ;
Schild, D .
BIOPHYSICAL JOURNAL, 2000, 79 (06) :3294-3306
[18]   Dynamics of fluorescence fluctuations in green fluorescent protein observed by fluorescence correlation spectroscopy [J].
Haupts, U ;
Maiti, S ;
Schwille, P ;
Webb, WW .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1998, 95 (23) :13573-13578
[19]   Simultaneous two-photon excitation of distinct labels for dual-color fluorescence crosscorrelation analysis [J].
Heinze, KG ;
Koltermann, A ;
Schwille, P .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2000, 97 (19) :10377-10382
[20]   Real-time enzyme kinetics monitored by dual-color fluorescence cross-correlation spectroscopy [J].
Kettling, U ;
Koltermann, A ;
Schwille, P ;
Eigen, M .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1998, 95 (04) :1416-1420