Formaldehyde levels in downtown Mexico City during 2003

被引:54
作者
Grutter, M [1 ]
Flores, E [1 ]
Andraca-Ayala, G [1 ]
Báez, A [1 ]
机构
[1] Univ Nacl Autonoma Mexico, Ctr Ciencias Atmosfera, Mexico City 05410, DF, Mexico
关键词
formaldehyde; Mexico City; OP-FTIR; DOAS; DNPH samplers;
D O I
10.1016/j.atmosenv.2004.10.031
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, two spectroscopic techniques and two DNPH-sampling techniques were operated simultaneously in a downtown site of Mexico City to accurately determine formaldehyde levels during February and October of 2003. 1-hour samples from DNPH-silica cartridges and 4-h samples with an annular denuder system were collected during 4 days. The results are compared with the continuous data provided by an open-path Fourier transform infrared spectrometer (OP-FTIR) and a differential optical absorption spectrometer (DOAS) along a 426m trajectory. Both spectroscopic techniques showed an agreement of 15% or less and a correlation coefficient of 0.86. The cartridge results presented average deviations relative to the OP-FTIR between -32% and 24% for the specific time periods but showed a clear similarity in the temporal patterns from the 5-min spectroscopic data. The results from the annular denuder samples show more limited precision (-35-65%) but the overall accuracy, when all data collected for the two 4-h periods was averaged, fell within a +/-15% deviation range. This sampling configuration allowed to estimate an amount of formaldehyde in the particulate matter (<2.5 mum) of about 20% from that found in the gas-phase. Monthly average concentrations ranged between 23.9 ppb during February and 12.7 ppb during October of 2003. A 35% decrease in the average-peak values between the dry and wet seasons was identified. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1027 / 1034
页数:8
相关论文
共 30 条
[1]   Sources and sinks of formaldehyde and acetaldehyde: An analysis of Denver's ambient concentration data [J].
Anderson, LG ;
Lanning, JA ;
Barrell, R ;
Miyagishima, J ;
Jones, RH ;
Wolfe, P .
ATMOSPHERIC ENVIRONMENT, 1996, 30 (12) :2113-2123
[2]  
ANDRACAAYALA G, 2004, UNPUB ATMOSFERA
[3]   2,4-DINITROPHENYLHYDRAZINE-COATED SILICA-GEL CARTRIDGE METHOD FOR DETERMINATION OF FORMALDEHYDE IN AIR - IDENTIFICATION OF AN OZONE INTERFERENCE [J].
ARNTS, RR ;
TEJADA, SB .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1989, 23 (11) :1428-1430
[4]   Carbonyl levels in indoor and outdoor air in Mexico City and Xalapa, Mexico [J].
Báez, A ;
Padilla, H ;
García, R ;
Torres, MD ;
Rosas, I ;
Belmont, R .
SCIENCE OF THE TOTAL ENVIRONMENT, 2003, 302 (1-3) :211-226
[5]  
Báez AP, 2000, ATMOSFERA, V13, P121
[6]   MEASUREMENTS OF FORMALDEHYDE AND ACETALDEHYDE IN THE ATMOSPHERE OF MEXICO-CITY [J].
BAEZ, AP ;
BELMONT, R ;
PADILLA, H .
ENVIRONMENTAL POLLUTION, 1995, 89 (02) :163-167
[7]   Preliminary study of the determination of ambient carbonyls in Xalapa City, Veracruz, Mexico [J].
Báez, AP ;
Padilla, H ;
Cervantes, J ;
Pereyra, D ;
Torres, MC ;
Garcia, R ;
Belmont, R .
ATMOSPHERIC ENVIRONMENT, 2001, 35 (10) :1813-1819
[8]   THE CHEMISTRY OF CARBONYL-COMPOUNDS IN THE ATMOSPHERE - A REVIEW [J].
CARLIER, P ;
HANNACHI, H ;
MOUVIER, G .
ATMOSPHERIC ENVIRONMENT, 1986, 20 (11) :2079-2099
[9]  
Finlayson-Pitts B. J., 2000, Chemistry of the Upper and Lower Atmosphere
[10]   Tunable diode laser absorption spectrometer for ground-based measurements of formaldehyde [J].
Fried, A ;
Sewell, S ;
Henry, B ;
Wert, BP ;
Gilpin, T ;
Drummond, JR .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1997, 102 (D5) :6253-6266