Correlation and digital signal processing techniques for the reduction of detection limits of bromate and bromide in model water samples by ion chromatography with direct ultraviolet detection

被引:6
作者
Kuldvee, R
Kaljurand, M
Smit, HC
机构
[1] Tallinn Univ Technol, Inst Chem, EE-0026 Tallinn, Estonia
[2] Univ Amsterdam, Analyt Chem Lab, NL-1018 WV Amsterdam, Netherlands
关键词
digital-signal processing techniques; signal processing; bromate; bromide;
D O I
10.1016/S0021-9673(97)00780-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Bromate is a well known by-product produced by the ozonation (disinfection) of drinking water, of which the concentration is considered to be regulated to a low mu g/l level, Successful ion chromatographic methods of determination involve the implementation of concentration columns. As an alternative to concentration, it is demonstrated that the low mu g/l level can easily be attained using a simple and foolproof experimental arrangement of direct pseudo random injections of large quantities of the sample and ultraviolet (UV) detection at 204 nm with subsequent decorrelation of the detector signal. The approach, known as correlation chromatography, makes high demands to the reproducibility and other properties of the injection system. Although correlation chromatography is less sensible to spikes and baseline drift compared with normal chromatography, optimum results will be achieved by applying digital detector processing prior to decorrelation, combined with a proper modification of the eluent. This is demonstrated here. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:247 / 257
页数:11
相关论文
共 11 条
[1]  
*BOOKL WAT CLEAN S, 1990, TALL EEST
[2]   TRACE-LEVEL DETERMINATION OF BROMATE IN OZONATED DRINKING-WATER USING ION CHROMATOGRAPHY [J].
JOYCE, RJ ;
DHILLON, HS .
JOURNAL OF CHROMATOGRAPHY A, 1994, 671 (1-2) :165-171
[3]  
JOYCE RJ, 1995, PITTSB C AN CHEM APP
[4]   CORRELATION ION CHROMATOGRAPHY WITH INDIRECT UV DETECTION [J].
KALJURAND, M ;
URBAS, E ;
HALDNA, U .
CHROMATOGRAPHIA, 1992, 34 (5-8) :417-420
[5]   IMPROVEMENT OF THE PERFORMANCE OF SINGLE-COLUMN ION CHROMATOGRAPHY BY COMPUTERIZED DETECTOR SIGNAL-PROCESSING AND CORRELATION CHROMATOGRAPHY [J].
KALJURAND, M ;
URBAS, E ;
HALDNA, U .
JOURNAL OF CHROMATOGRAPHY A, 1994, 660 (1-2) :147-152
[6]  
KALJURAND M, 1989, COMPUTERISED MULTIPL
[7]  
LAEVEN JM, 1987, ANAL CHIM ACTA, V194, P1
[8]   SIMULTANEOUS CORRELATION CHROMATOGRAPHY, A NEW TECHNIQUE APPLIED TO CALIBRATION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
SMIT, HC ;
MARS, C ;
KRAAK, JC .
ANALYTICA CHIMICA ACTA, 1986, 181 :37-49
[9]  
*US EPA, 1989, DET IN AN WAT ION CH
[10]  
VONGUNTEN U, 1993, 11 OZ WORLD C SAN FR