3-D reconstruction from tomographic data using 2-D active contours

被引:7
作者
Chung, R [1 ]
Ho, CK [1 ]
机构
[1] Chinese Univ Hong Kong, Dept Mech & Automat Engn, Shatin, Hong Kong, Peoples R China
来源
COMPUTERS AND BIOMEDICAL RESEARCH | 2000年 / 33卷 / 03期
关键词
medical image processing; computed tomography; volumetric reconstruction; deformable model;
D O I
10.1006/cbmr.2000.1541
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Reconstructing three-dimensional (3-D) shapes of structures like internal organs from tomographic data is an important problem in medical imaging. Various forms of the deformable surface model have been proposed to tackle it, but they are either computationally expensive or limited to tubular shapes. In this paper a 3-D reconstruction mechanism that requires only 2-D deformations is proposed. Advantages of the proposed model include that it is conformable to any 3-D shape, efficient, and highly parallelizable. Most importantly, it requires from the user an initial 2-D contour on only one of the tomograph slices to start with. Experimental results are shown to illustrate the performance of the model. (C) 2000 Academic Press.
引用
收藏
页码:186 / 210
页数:25
相关论文
共 9 条
[1]   3-D SEGMENTATION OF MR IMAGES OF THE HEAD FOR 3-D DISPLAY [J].
BOMANS, M ;
HOHNE, KH ;
TIEDE, U ;
RIEMER, M .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1990, 9 (02) :177-183
[2]  
Chung R., 1996, Proceedings of the 13th International Conference on Pattern Recognition, P849, DOI 10.1109/ICPR.1996.546144
[3]   ON ACTIVE CONTOUR MODELS AND BALLOONS [J].
COHEN, LD .
CVGIP-IMAGE UNDERSTANDING, 1991, 53 (02) :211-218
[4]   FINITE-ELEMENT METHODS FOR ACTIVE CONTOUR MODELS AND BALLOONS FOR 2-D AND 3-D IMAGES [J].
COHEN, LD ;
COHEN, I .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1993, 15 (11) :1131-1147
[5]   3-DIMENSIONAL IMAGING [J].
FISHMAN, EK ;
MAGID, D ;
NEY, DR ;
CHANEY, EL ;
PIZER, SM ;
ROSENMAN, JG ;
LEVIN, DN ;
VANNIER, MW ;
KUHLMAN, JE ;
ROBERTSON, DD .
RADIOLOGY, 1991, 181 (02) :321-337
[6]   3-DIMENSIONAL SURFACE RECONSTRUCTIONS USING A GENERAL-PURPOSE IMAGE-PROCESSING SYSTEM [J].
HOFFMEISTER, JW ;
RINEHART, GC ;
VANNIER, MW .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1990, 14 (01) :35-42
[7]   SNAKES - ACTIVE CONTOUR MODELS [J].
KASS, M ;
WITKIN, A ;
TERZOPOULOS, D .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 1987, 1 (04) :321-331
[8]   DYNAMIC ELASTIC INTERPOLATION FOR 3-D MEDICAL IMAGE-RECONSTRUCTION FROM SERIAL CROSS-SECTIONS [J].
LIN, WC ;
LIANG, CC ;
CHEN, CT .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (03) :225-232
[9]   3-DIMENSIONAL CT OF CENTRAL LUNG-TUMORS [J].
QUINT, LE ;
MCSHAN, DL ;
GLAZER, GM ;
ORRINGER, MB ;
FRANCIS, IR ;
GROSS, BH .
CLINICAL IMAGING, 1990, 14 (04) :323-329