Development of a chemiluminescent optical fiber immunosensor to detect Streptococcus pneumoniae antipolysaccharide antibodies

被引:17
作者
Marks, RS
Margalit, A
Bychenko, A
Bassis, E
Porat, N
Dagan, R
机构
[1] Soroka Univ, Unit Biotechnol, IL-84105 Beer Sheva, Israel
[2] Soroka Univ, Inst Appl Biosci, IL-84105 Beer Sheva, Israel
[3] Soroka Univ, Pediat Infect Dis Unit, IL-84105 Beer Sheva, Israel
[4] Ben Gurion Univ Negev, Fac Hlth Sci, IL-84105 Beer Sheva, Israel
关键词
optical fiber; chemiluminescence; immunosensor; Streptococcus pneumoniae;
D O I
10.1385/ABAB:89:2-3:117
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A chemiluminescent-based optical fiber immunosensor was developed for the detection of antipneumococcal antibodies. This was accomplished by developing a different chemical procedure utilizing 3-aminopropyl trimethoxysilane and cyanuric chloride to conjugate pneumococcal cell wall polysaccharides to the optical fiber tips, and by improving the sensitivity of the photodetection system. The lowest titer of antipneumococcal antibodies detected by the optical fiber was at a 1:819,200 dilution. The lowest corresponding value by standard enzyme-linked immunosorbent assay was at a 1:98,415 dilution. It was concluded that the optical immunosensor system is an accurate and sensitive method to detect antipneumococcal antibodies and may be an adequate tool to monitor antibodies in specimens such as saliva and urine.
引用
收藏
页码:117 / 126
页数:10
相关论文
共 19 条
[1]  
AHLUWALIA A, 1991, MEAS SCI TECHNOL, V3, P1166
[2]   ANTIMICROBIAL RESISTANCE IN STREPTOCOCCUS-PNEUMONIAE - AN OVERVIEW [J].
APPELBAUM, PC .
CLINICAL INFECTIOUS DISEASES, 1992, 15 (01) :77-83
[3]  
DAGAN R, 1995, 35 INT C ANT AG CHEM, pG1
[4]  
DEVELASCO EA, 1995, MICROBIOL REV, V59, P598
[5]   RATIONAL DESIGN OF CONJUGATE VACCINES [J].
DINTZIS, RZ .
PEDIATRIC RESEARCH, 1992, 32 (04) :376-385
[6]   COVALENT COUPLING OF POLYSACCHARIDES TO SILICON AND SILICON RUBBER SURFACES [J].
ELAM, JH ;
NYGREN, H ;
STENBERG, M .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1984, 18 (08) :953-959
[7]  
HALE ZM, 1994, P SOC PHOTO-OPT INS, V2131, P484, DOI 10.1117/12.180745
[8]   The single mode tapered optical fibre loop immunosensor [J].
Hale, ZM ;
Payne, FP ;
Marks, RS ;
Lowe, CR ;
Levine, MM .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (1-2) :137-148
[9]   ANTI-CAPSULAR POLYSACCHARIDE ANTIBODY CONCENTRATIONS IN SALIVA AFTER IMMUNIZATION WITH HAEMOPHILUS-INFLUENZAE TYPE-B CONJUGATE VACCINES [J].
KAUPPI, M ;
ESKOLA, J ;
KAYHTY, H .
PEDIATRIC INFECTIOUS DISEASE JOURNAL, 1995, 14 (04) :286-294
[10]  
LARSEN HS, 1995, TXB DIAGNOSTIC MICRO, P341