Echocardiographic and invasive measurements of pulmonary artery pressure correlate closely at high altitude

被引:110
作者
Allemann, Y [1 ]
Sartori, C
Lepori, M
Pierre, S
Mélot, C
Naeije, R
Scherrer, U
Maggiorini, M
机构
[1] Univ Hosp Bern, Div Cardiol, Swiss Cardiovasc Ctr Bern, CH-3010 Bern, Switzerland
[2] CHU Vaudois, Dept Internal Med, CH-1011 Lausanne, Switzerland
[3] Erasme Univ Hosp, Lab Cardiovasc & Resp Physiol, B-1070 Brussels, Belgium
[4] Univ Zurich Hosp, Dept Internal Med, Med Intens Care Unit, CH-8091 Zurich, Switzerland
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 2000年 / 279卷 / 04期
关键词
Doppler echocardiography; right heart catheterization; high-altitude pulmonary edema;
D O I
10.1152/ajpheart.2000.279.4.H2013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Exaggerated hypoxia-induced pulmonary hypertension is a hallmark of high-altitude pulmonary edema (HAPE) and plays a major role in its pathogenesis. Many studies of HAPE have estimated systolic pulmonary arterial pressure (SPAP) with Doppler echocardiography. Whereas at low altitude, Doppler echocardiographic estimation of SPAP correlates closely with its invasive measurement, no such evidence exists for estimations obtained at high altitude, where alterations of blood viscosity may invalidate the simplified Bernoulli equation. We measured SPAP by Doppler echocardiography and invasively in 14 mountaineers prone to HAPE and in 14 mountaineers resistant to this condition at 4,559 m. Mountaineers prone to HAPE had more pronounced pulmonary hypertension (57 +/- 12 and 58 +/- 10 mmHg for noninvasive and invasive determination, respectively; means +/- SD) than subjects resistant to HAPE (37 +/- 8 and 37 +/- 6 mmHg, respectively), and the values measured in the two groups as a whole covered a wide range of pulmonary arterial pressures (30-83 mmHg). Spearman test showed a highly significant correlation (r = 0.89, P< 0.0001) between estimated and invasively measured SPAP values. The mean difference between invasively measured and Doppler-estimated SPAP was 0.5 +/- 8 mmHg. At high altitude, estimation of SPAP by Doppler echocardiography is an accurate and reproducible method that correlates closely with its invasive measurement.
引用
收藏
页码:H2013 / H2016
页数:4
相关论文
共 14 条
[1]  
Antezana G, 1982, HIGH ALTITUDE PHYSL, P232
[2]   QUANTITATIVE ASSESSMENT OF PULMONARY-HYPERTENSION IN PATIENTS WITH TRICUSPID REGURGITATION USING CONTINUOUS WAVE DOPPLER ULTRASOUND [J].
BERGER, M ;
HAIMOWITZ, A ;
VANTOSH, A ;
BERDOFF, RL ;
GOLDBERG, E .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (02) :359-365
[3]   CONTINUOUS WAVE DOPPLER DETERMINATION OF RIGHT VENTRICULAR PRESSURE - A SIMULTANEOUS DOPPLER-CATHETERIZATION STUDY IN 127 PATIENTS [J].
CURRIE, PJ ;
SEWARD, JB ;
CHAN, KL ;
FYFE, DA ;
HAGLER, DJ ;
MAIR, DD ;
REEDER, GS ;
NISHIMURA, RA ;
TAJIK, AJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (04) :750-756
[4]  
HATLE L, 1978, BRIT HEART J, V40, P131
[5]   PHYSIOLOGIC STUDIES OF PULMONARY EDEMA AT HIGH ALTITUDE [J].
HULTGREN, HN ;
LOPEZ, CE ;
LUNDBERG, E ;
MILLER, H .
CIRCULATION, 1964, 29 (03) :393-&
[6]   High altitude pulmonary edema: Hemodynamic aspects [J].
Hultgren, HN .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1997, 18 (01) :20-25
[7]  
OELZ O, 1989, LANCET, V2, P1241
[8]   BLOOD RHEOLOGY IN ACUTE MOUNTAIN-SICKNESS AND HIGH-ALTITUDE PULMONARY-EDEMA [J].
REINHART, WH ;
KAYSER, B ;
SINGH, A ;
WABER, U ;
OELZ, O ;
BARTSCH, P .
JOURNAL OF APPLIED PHYSIOLOGY, 1991, 71 (03) :934-938
[9]  
ROY SB, 1969, BRIT HEART J, V31, P52
[10]  
Sartori C, 1997, Cardiologia, V42, P559