View-synchronized robotic image-guided therapy for atrial fibrillation ablation - Experimental validation and clinical feasibility

被引:75
作者
Reddy, Vivek Y.
Neuzil, Petr
Malchano, Zachary J.
Vijaykumar, Ragu
Cury, Ricardo
Abbara, Suhny
Weichet, Jiri
McPherson, Christina D.
Ruskin, Jeremy N.
机构
[1] Massachusetts Gen Hosp, Cardiac Arrhythmia Serv, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[3] Harvard Univ, Sch Med, Boston, MA 02115 USA
[4] Homolka Hosp, Prague, Czech Republic
关键词
catheter ablation; tomography; x-ray computed; fibrillation; imaging; mapping;
D O I
10.1161/CIRCULATIONAHA.106.677369
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - A robotic catheter navigation system has been developed that provides a significant degree of freedom of catheter movement. This study examines the feasibility of synchronizing this robotic navigation system with electroanatomic mapping and 3-dimensional computed tomography imaging to perform view- synchronized left atrial (LA) ablation. Methods and Results - This study consisted of a porcine experimental validation phase (9 animals) and a clinical feasibility phase (9 atrial fibrillation patients). Preprocedural computed tomography images were reconstructed to provide 3-dimensional surface models of the LA pulmonary veins and aorta. Aortic electroanatomic mapping was performed manually, followed by registration with the corresponding computed tomography aorta image using custom software. The mapping catheter was remotely manipulated with the robotic navigation system within the registered computed tomography image of the LA pulmonary veins. The point-to-surface error between the LA electroanatomic mapping data and the computed tomography image was 2.1 +/- 0.7 and 1.6 +/- 0.1 mm in the preclinical and clinical studies, respectively. The catheter was remotely navigated into all pulmonary veins, the LA appendage, and circumferentially along the mitral valve annulus. In 7 of 9 animals, circumferential radiofrequency ablation lesions were applied periostially to ablate 11 pulmonary veins. In patients, all of the pulmonary veins were remotely electrically isolated in an extraostial fashion. Adjunctive ablation included superior vena cava isolation in 6 patients, cavotricuspid isthmus ablation in 5 patients, and ablation of sites of complex fractionated activity and atypical LA flutters in 3 patients. Conclusions - This study demonstrates the safety and feasibility of an emerging paradigm for atrial fibrillation ablation involving the confluence of 3 technologies: 3-dimensional imaging, electroanatomic mapping, and remote robotic navigation.
引用
收藏
页码:2705 / 2714
页数:10
相关论文
共 14 条
[1]   Early experience with a computerized robotically controlled catheter system [J].
Al-Ahmad, A ;
Grossman, JD ;
Wang, PJ .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2005, 12 (03) :199-202
[2]   Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins - Electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation [J].
Chen, SA ;
Hsieh, MH ;
Tai, CT ;
Tsai, CF ;
Prakash, VS ;
Yu, WC ;
Hsu, TL ;
Ding, YA ;
Chang, MS .
CIRCULATION, 1999, 100 (18) :1879-1886
[3]   Initial experience with remote catheter ablation using a novel magnetic navigation system -: Magnetic remote catheter ablation [J].
Ernst, S ;
Ouyang, FF ;
Linder, C ;
Hertting, K ;
Stahl, F ;
Chun, J ;
Hachiya, H ;
Bänsch, D ;
Antz, M ;
Kuck, KH .
CIRCULATION, 2004, 109 (12) :1472-1475
[4]   Magnetic guidance system for cardiac electrophysiology - A prospective trial of safety and efficacy in humans [J].
Faddis, MN ;
Chen, J ;
Osborn, J ;
Talcott, M ;
Cain, ME ;
Lindsay, BD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (11) :1952-1958
[5]  
Gepstein L, 1997, CIRCULATION, V95, P1611
[6]   Ablation therapy for atrial fibrillation (AF):: Past, present and future [J].
Jaïs, P ;
Weerasooriya, R ;
Shah, DC ;
Hocini, M ;
Macle, L ;
Choi, KJ ;
Scavee, C ;
Haïssaguerre, M ;
Clémenty, J .
CARDIOVASCULAR RESEARCH, 2002, 54 (02) :337-346
[7]   Circular mapping and ablation of the pulmonary vein for treatment of atrial fibrillation - Impact of different catheter technologies [J].
Marrouche, NF ;
Dresing, T ;
Cole, C ;
Bash, D ;
Saad, E ;
Balaban, K ;
Pavia, SV ;
Schweikert, R ;
Saliba, W ;
Abdul-Karim, A ;
Pisano, E ;
Fanelli, R ;
Tchou, P ;
Natale, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (03) :464-474
[8]   A new approach for catheter ablation of atrial fibrillation: Mapping of the electrophysiologic substrate [J].
Nademanee, K ;
McKenzie, J ;
Kosar, E ;
Schwab, M ;
Sunsaneewitayakul, B ;
Vasavakul, T ;
Khunnawat, C ;
Ngarmukos, T .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (11) :2044-2053
[9]  
NIKAELIAN BJ, 2005, CIRCULATION, V112, pE35
[10]   The impact of respiration on left atrial and pulmonary venous anatomy: Implications for image-guided intervention [J].
Noseworthy, PA ;
Malchano, ZJ ;
Ahmed, J ;
Holmvang, G ;
Ruskin, JN ;
Reddy, VY .
HEART RHYTHM, 2005, 2 (11) :1173-1178