Peri-implant hard and soft tissue integration to dental implants made of titanium and gold

被引:39
作者
Abrahamsson, Ingemar [1 ]
Cardaropoli, Giuseppe [1 ]
机构
[1] Gothenburg Univ, Sahlgrenska Acad, Dept Periodontol, S-40530 Gothenburg, Sweden
关键词
biocompatibility; biomaterials; gold alloy; histometry; morphometry; osseointegration; peri-implant tissues; titanium;
D O I
10.1111/j.1600-0501.2006.01326.x
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
Objectives: The aim of the study is to compare the peri-implant hard and soft tissue integration around dental implants made of commercially pure (c.p.) titanium or a gold alloy but with the same shape and surface roughness. Material and methods: In four beagle dogs, all mandibular premolars were extracted. Three months later, four experimental non-submerged implants were placed in each edentulous premolar region. Each implant comprised three different zones: zone A (coronal), zone B (central) and zone C (apical). Each zone was made of either c.p. titanium or a gold alloy. Four different combinations of metal and zone were used. A plaque control program was initiated and 6 months later, the animals were sacrificed and biopsies were obtained. The biopsies including the implant and the surrounding tissues were processed for ground sectioning. Results: The height of the peri-implant mucosa and the length of the barrier epithelium were similar at the four experimental sites. The marginal bone level in the different metal combinations was located between 4.5 and 4.8 mm apical of the implant rim. The percent of mineralized bone that was in direct contact with the implant surface (BIC%) was consistently greater in the marginal than in the apical portion of the implants. The BIC% for the marginal and apical zone were consistently greater for implant portions made of titanium than for portions made of gold alloy (zone B: 42.7% vs. 36.5%, zone C: 33.2% vs. 19%). Conclusions: Osseointegration was achieved to surfaces made of both c.p. titanium and a gold alloy. BIC% was higher at titanium than at gold surfaces. Moreover, the peri-implant soft tissue dimensions were not influenced by the metal used in the 'marginal' zone of the implant.
引用
收藏
页码:269 / 274
页数:6
相关论文
共 30 条
[1]
Early bone formation adjacent to rough and turned endosseous implant surfaces - An experimental study in the dog [J].
Abrahamsson, I ;
Berglundh, T ;
Linder, E ;
Lang, NP ;
Lindhe, J .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (04) :381-392
[2]
Abrahamsson I, 2001, INT J ORAL MAX IMPL, V16, P323
[3]
The mucosal attachment at different abutments - An experimental study in dogs [J].
Abrahamsson, I ;
Berglundh, T ;
Glantz, PO ;
Lindhe, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1998, 25 (09) :721-727
[4]
The mucosal barrier following abutment dis/reconnection - An experimental study in dogs [J].
Abrahamsson, I ;
Berglundh, T ;
Lindhe, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1997, 24 (08) :568-572
[5]
Akagawa Yasumasa, 2003, Int J Prosthodont, V16 Suppl, P28
[6]
OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN [J].
ALBREKTSSON, T ;
BRANEMARK, PI ;
HANSSON, HA ;
LINDSTROM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02) :155-170
[7]
Albrektsson T, 2004, INT J PROSTHODONT, V17, P536
[8]
ALBREKTSSON T, 1982, ADV BIOMATERIALS CLI, V4, P166
[9]
Albrektsson Tomas, 2003, Int J Prosthodont, V16 Suppl, P29
[10]
BRANEMARK PI, 1985, TISSUE INTEGRATED PR, V1, P11