Silver ion-selective electrodes employing Schiff base p-tert-butyl calix[4]arene derivatives as neutral carriers

被引:94
作者
Mahajan, RK [1 ]
Kaur, I [1 ]
Kumar, M [1 ]
机构
[1] Guru Nanak Dev Univ, Dept Chem, Amritsar 143005, Punjab, India
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2003年 / 91卷 / 1-3期
关键词
silver ion; sensor; calix[4]arene; Schiff base;
D O I
10.1016/S0925-4005(03)00062-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The potentiometric response characteristics and selectivity properties of poly(vinylchloride) (PVC) matrix membrane ion-selective electrodes for silver(I) ion, based on Schiff base p-tert-butyl calix[4]arene derivatives containing N and O as binding sites, were examined. These derivatives proves to work well with silver ions and corresponding electrodes display an excellent response to this ion. These electrodes works well over wide range of concentration (1.0 x 10(-5) to 1.0 x 10(-1) M) with a Nernstian slope. The electrodes have a fast response time of 20 s and operates in the wide pH range. These calix[4]arene derivatives, each showed excellent selectivities in ISE membrane electrodes with log K-Ag,M(pot) around -4.5 against some of the alkali, alkaline and transition metals, even against the strongest interferent, Hg2+ ions, the value was around -3.0. These silver(I) ion-selective electrodes were used as an indicator electrode for potentiometric titration of silver(l) using standard solution of sodium chloride, a sharp potential change occur at the end point. These ISEs were also used to determine low concentration of silver(I) ion in partially non-aqueous medium. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:26 / 31
页数:6
相关论文
共 15 条
[1]   SILVER(I) ION-SELECTIVE ELECTRODES BASED ON POLYTHIA-MACROCYCLES [J].
CASABO, J ;
MESTRES, L ;
ESCRICHE, L ;
TEIXIDOR, F ;
PEREZJIMENEZ, C .
JOURNAL OF THE CHEMICAL SOCIETY-DALTON TRANSACTIONS, 1991, (08) :1969-1971
[2]   Calixarene derivatives as the sensory molecules for silver ion-selective electrode [J].
Chen, LX ;
Zeng, XS ;
Ju, HF ;
He, XW ;
Zhang, ZZ .
MICROCHEMICAL JOURNAL, 2000, 65 (02) :129-135
[3]   Sensor molecules for silver(I)-selective membranes based on mono- to quadri-dentate podands [J].
Chung, S ;
Kim, W ;
Park, SB ;
Yoon, I ;
Lee, SS ;
Sung, DD .
CHEMICAL COMMUNICATIONS, 1997, (10) :965-966
[4]   TRANSDUCTION OF SELECTIVE RECOGNITION OF HEAVY-METAL IONS BY CHEMICALLY MODIFIED FIELD-EFFECT TRANSISTORS (CHEMFETS) [J].
COBBEN, PLHM ;
EGBERINK, RJM ;
BOMER, JG ;
BERGVELD, P ;
VERBOOM, W ;
REINHOUDT, DN .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1992, 114 (26) :10573-10582
[5]   Macrocycle based membrane sensors for the determination of cobalt(II) ions [J].
Jain, AK ;
Gupta, VK ;
Singh, LP ;
Khurana, U .
ANALYST, 1997, 122 (06) :583-586
[6]   Synthesis of new bis-calix[4]arenes with imine linkages. A search for new silver-selective sensors [J].
Kumar, M ;
Mahajan, RK ;
Sharma, V ;
Singh, H ;
Sharma, N ;
Kaur, I .
TETRAHEDRON LETTERS, 2001, 42 (31) :5315-5318
[7]   Molecular design of crown ethers.: 19.: Synthesis of novel disulfide- and diselenide-bridged bis(benzo-12-crown-4)s and their Ag+-selective electrode properties [J].
Liu, Y ;
Zhang, HY ;
Chen, LX ;
He, XW ;
Wada, T ;
Inoue, Y .
JOURNAL OF ORGANIC CHEMISTRY, 2000, 65 (10) :2870-2874
[8]   Liquid membrane transport and silver selective electrode based on novel bis(3-pyridinecarboxylate) calix[4]arene as ionophore [J].
Liu, Y ;
Zhao, BT ;
Chen, LX ;
He, XW .
MICROCHEMICAL JOURNAL, 2000, 65 (01) :75-79
[9]   Silver(I) ion selective PVC membrane based on bis-pyridine tetramide macrocycle [J].
Mahajan, RK ;
Parkash, O .
TALANTA, 2000, 52 (04) :691-693
[10]   Cesium ion selective electrode based on calix[4]crown ether-ester [J].
Mahajan, RK ;
Kumar, M ;
Sharma, V ;
Kaur, I .
TALANTA, 2002, 58 (03) :445-450