Design of a portable near infrared system for topographic imaging of the brain in babies

被引:29
作者
Vaithianathan, T [1 ]
Tullis, IDC
Everdell, N
Leung, T
Gibson, A
Meek, J
Delpy, DT
机构
[1] UCL, Dept Med Phys & Bioengn, London WC1E 6JA, England
[2] UCL, Dept Paediat & Child Hlth, London WC1E 6JJ, England
关键词
D O I
10.1063/1.1775314
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 [仪器科学与技术]; 080401 [精密仪器及机械]; 081102 [检测技术与自动化装置];
摘要
A portable topographic near-infrared spectroscopic (NIRS) imaging system has been developed to provide real-time temporal and spatial information about the cortical response to stimulation in unrestrained infants. The optical sensing array is lightweight, flexible, and easy to apply to infants ranging from premature babies in intensive care to children in a normal environment. The sensor pad consists of a flexible double-sided circuit board onto which are mounted multiple sources (light-emitting diodes) and multiple detectors (p-i-n photodiodes), all electrically encapsulated in silicone rubber. The control electronics are housed in a box with a medical grade isolated power supply and linked to a PC fitted with a data acquisition card, the signal acquisition and analysis being performed using LABVIEW(TM). The signal output is displayed as an image of oxy- and deoxyhemoglobin concentration ([HbO(2)], [Hb]) changes at a frame rate of 3 Hz. Experiments have been conducted on phantoms to determine the sensitivity of the system, and the results have been compared to theoretical simulations. The system has been tested in volunteers by imaging changes in forearm muscle oxygenation, following blood pressure cuff occlusion to obtain typical [Hb] and [HbO(2)] plots. (C) 2004 American Institute of Physics.
引用
收藏
页码:3276 / 3283
页数:8
相关论文
共 40 条
[1]
Optical imaging in medicine .2. Modelling and reconstruction [J].
Arridge, SR ;
Hebden, JC .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (05) :841-853
[2]
PHOTON-MEASUREMENT DENSITY-FUNCTIONS .2. FINITE-ELEMENT-METHOD CALCULATIONS [J].
ARRIDGE, SR ;
SCHWEIGER, M .
APPLIED OPTICS, 1995, 34 (34) :8026-8037
[3]
Optical tomography in medical imaging [J].
Arridge, SR .
INVERSE PROBLEMS, 1999, 15 (02) :R41-R93
[4]
Precision localization of hidden absorbers in body tissues with phased-array optical systems [J].
Chance, B ;
Kang, KA ;
He, LB ;
Liu, HL ;
Zhou, SM .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (12) :4324-4332
[5]
CHANCE B, 1988, ANN NY ACAD SCI, V551, P1, DOI 10.1111/j.1749-6632.1988.tb22316.x
[6]
TIME-RESOLVED SPECTROSCOPY OF HEMOGLOBIN AND MYOGLOBIN IN RESTING AND ISCHEMIC MUSCLE [J].
CHANCE, B ;
NIOKA, S ;
KENT, J ;
MCCULLY, K ;
FOUNTAIN, M ;
GREENFELD, R ;
HOLTOM, G .
ANALYTICAL BIOCHEMISTRY, 1988, 174 (02) :698-707
[7]
CHANCE B, 2002, OSA BIOM TOP M, P450
[8]
Multichannel time-resolved optical tomographic imaging system [J].
Eda, H ;
Oda, I ;
Ito, Y ;
Wada, Y ;
Oikawa, Y ;
Tsunazawa, Y ;
Takada, M ;
Tsuchiya, Y ;
Yamashita, Y ;
Oda, M ;
Sassaroli, A ;
Yamada, Y ;
Tamura, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (09) :3595-3602
[9]
A DESIGN FOR A STABLE AND REPRODUCIBLE PHANTOM FOR USE IN NEAR-INFRARED IMAGING AND SPECTROSCOPY [J].
FIRBANK, M ;
DELPY, DT .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (06) :847-853
[10]
On-line optical imaging of the human brain with 160-ms temporal resolution [J].
Franceschini, MA ;
Toronov, V ;
Filiaci, ME ;
Gratton, E ;
Fantini, S .
OPTICS EXPRESS, 2000, 6 (03) :49-57