Is a mixture of gadolinium and iodinated contract material safe during MR arthrography?

被引:42
作者
Brown, RR
Clarke, DW
Daffner, RH
机构
[1] Cleveland Clin, Dept Radiol, Ft Lauderdale, FL 33309 USA
[2] Albany Med Coll Union Univ, Albany Coll Pharm, Albany, NY 12208 USA
[3] Allegheny Gen Hosp, Dept Radiol, Pittsburgh, PA 15212 USA
关键词
D O I
10.2214/ajr.175.4.1751087
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. This study was designed to determine whether a mixture of iodinated contrast material and gadopentetate dimeglumine used during MR arthrography yields free gadolinium ion, a systemically toxic metal. MATERIALS AND METHODS, Mixtures of commercially available nonionic and ionic iodinated contrast agent, gadopentetate dimeglumine, lidocaine, and epinephrine were analyzed using a spectrophotometric titration with a gadolinium ion titrant and methyl thymol blue indicator. RESULTS. We found no significant dissociation of gadolinium ion when gadopentetate dimeglumine was mixed with iodinated contrast agents, lidocaine, or epinephrine in any of the dilutions tested. CONCLUSION. Gadopentetate dimeglumine and iodinated contrast material can be mixed before MR imaging without any release of free gadolinium and are therefore safe for confirming the intraarticular placement of contrast material before MR arthrography.
引用
收藏
页码:1087 / 1090
页数:4
相关论文
共 7 条
[1]   MAGNETIC-RESONANCE KNEE ARTHROGRAPHY - ENHANCED CONTRAST BY GADOLINIUM COMPLEX IN THE RABBIT AND IN HUMANS [J].
ENGEL, A .
ACTA ORTHOPAEDICA SCANDINAVICA, 1990, 61 :3-+
[2]   SAFETY ASSESSMENT OF GADOPENTETATE DIMEGLUMINE IN UNITED-STATES CLINICAL-TRIALS [J].
GOLDSTEIN, HA ;
KASHANIAN, FK ;
BLUMETTI, RF ;
HOLYOAK, WL ;
HUGO, FP ;
BLUMENFIELD, DM .
RADIOLOGY, 1990, 174 (01) :17-23
[3]   THE EFFECT OF INTRAARTICULAR GADOLINIUM-DTPA ON SYNOVIAL-MEMBRANE AND CARTILAGE [J].
HAJEK, PC ;
SARTORIS, DJ ;
GYLYSMORIN, V ;
HAGHIGHI, P ;
ENGEL, A ;
KRAMER, F ;
NEUMANN, CH ;
RESNICK, D .
INVESTIGATIVE RADIOLOGY, 1990, 25 (02) :179-183
[4]   MR ARTHROGRAPHY OF THE SHOULDER WITH GADOPENTETATE DIMEGLUMINE - INFLUENCE OF CONCENTRATION, IODINATED CONTRAST MATERIAL, AND TIME ON SIGNAL INTENSITY [J].
KOPKA, L ;
FUNKE, M ;
FISCHER, U ;
KEATING, D ;
OESTMANN, J ;
GRABBE, E .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (03) :621-623
[5]   PROTONATED, HYDROXO AND MIXED PROTONATED-HYDROXO COMPLEX EQUILIBRIA OF THE RARE-EARTH IONS WITH METHYL THYMOL BLUE [J].
NAYAN, R .
JOURNAL OF INORGANIC & NUCLEAR CHEMISTRY, 1980, 42 (12) :1743-1747
[6]   CLINICAL SAFETY OF GADOPENTETATE DIMEGLUMINE [J].
NELSON, KL ;
GIFFORD, LM ;
LAUBERHUBER, C ;
GROSS, CA ;
LASSER, TA .
RADIOLOGY, 1995, 196 (02) :439-443
[7]  
Powell JE., 1979, HDB PHYS CHEM RARE E, P81