Assessment of the safety of intrauterine instillation of heated saline for endometrial ablation

被引:22
作者
Bustos-Lopez, HH
Baggish, M
Valle, RF
Vadillo-Ortega, F
Ibarra, V
Nava, G
机构
[1] Inst Nacl Infertil, Inst Nacl Perinatol, Dept Infertil, Mexico City 1000, DF, Mexico
[2] Inst Nacl Perinatol, Dept Gynecol, Mexico City 1000, DF, Mexico
[3] Good Samaritan Hosp, Dept Obstet & Gynecol, Cincinnati, OH USA
[4] Northwestern Univ, Prentice Womens Hosp, Sch Med, Dept Obstet & Gynecol, Chicago, IL 60611 USA
[5] Northwestern Univ, Sch Med, Matern Ctr, Chicago, IL 60611 USA
[6] Inst Nacl Nutr Salvador Zubiran, Dept Reprod Biol, Mexico City 14000, DF, Mexico
关键词
endometrial ablation; temperature-controlled heated saline; hysteroscopy;
D O I
10.1016/S0015-0282(97)00456-1
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To evaluate the safety of pressure, temperature-controlled, continuously circulating hot saline (EnAbl(TM) system, InnerDyne Medical, Sunnyvale, CA) for endometrial ablation using the in vivo human uterus. Design: Clinical safety study. Setting: An academic research environment, Patients: Eleven women undergoing abdominal hysterectomy because of abnormal uterine bleeding. Intervention: Before uterine removal, endometrial cavities were exposed to 15 minutes of recirculatory normal saline heated to 70-85 degrees C. Main Outcome Measure(s): The uteri were analyzed for extent of thermal damage using standard histopathological techniques and tissue viability histochemical staining. Intrauterine pressures and serosal and subserosal temperatures were continuously monitored by computer. Result(s): In each treated specimen, histochemical staining demonstrated a depth of necrosis that extended through the entire endometrium and approximately 1-2 mm into the myometrium, The control specimen showed no thermal or mechanical damage. There were no observed negative effects or related complications with this system, Conclusion(s): The computer-controlled system employing continuously circulating hot saline is an effective method to destroy the endometrium. In four cases with clearly patent tubes, no spill was observed. In all 11 patients, serosal and subserosal temperatures were within safe levels (mean temperature, 37 degrees C). ((C) 1998 by American Society for Reproductive Medicine.).
引用
收藏
页码:155 / 160
页数:6
相关论文
共 15 条
[1]   A computer-controlled, continuously circulating, hot irrigating system for endometrial ablation [J].
Baggish, M ;
Paraiso, M ;
Breznock, EM ;
Griffey, S .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1995, 173 (06) :1842-1848
[2]   Endometrial ablation: A series of 568 patients treated over an 11-year period [J].
Baggish, MS ;
Sze, EHM .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1996, 174 (03) :908-913
[3]   THRESHOLD INTRAUTERINE PERFUSION PRESSURES FOR INTRAPERITONEAL SPILL DURING HYDROTUBATION AND CORRELATION WITH TUBAL ADHESIVE DISEASE [J].
BAKER, VL ;
ADAMSON, GD .
FERTILITY AND STERILITY, 1995, 64 (06) :1066-1069
[4]  
BUSTOSLOPEZ HH, 1997, PERINATOL REPROD HUM, V11, P33
[5]  
FUJIMOTO S, 1989, CANCER-AM CANCER SOC, V64, P154, DOI 10.1002/1097-0142(19890701)64:1<154::AID-CNCR2820640126>3.0.CO
[6]  
2-8
[7]  
Garry R, 1992, GYNAECOL ENDOSC, V1, P23
[8]   LASER PHOTOVAPORIZATION OF ENDOMETRIUM FOR THE TREATMENT OF MENORRHAGIA [J].
GOLDRATH, MH ;
FULLER, TA ;
SEGAL, S .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1981, 140 (01) :14-19
[9]  
INDMAN PD, 1992, J REPROD MED, V37, P667
[10]  
NEUWIRTH RS, 1994, OBSTET GYNECOL, V83, P792