Anatomy of the superficial peroneal nerve in relation to fixation of tibia fractures with the Less Invasive Stabilization System

被引:59
作者
DeAngelis, JP [1 ]
DeAngelis, NA [1 ]
Anderson, R [1 ]
机构
[1] Univ Massachusetts, Sch Med, Dept Orthoped & Phys Rehabil, Worcester, MA USA
关键词
Less Invasive Stabilization System; tibia fracture; superficial peroneal nerve;
D O I
10.1097/00005131-200409000-00009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To examine the danger to the superficial peroneal nerve during percutaneous screw placement in the distal holes of the 13-hole proximal tibia Less Invasive Stabilization System plate in a cadaver. Design: Anatomic study. Setting: Medical school anatomy laboratory. Interventions: Fourteen adult cadaveric lower extremities were used. A 13-hole proximal tibia Less Invasive Stabilization System plate was placed as described by the manufacturer. Dissection of the superficial peroneal nerve was performed following localization of screw holes 7 through 13 using insertion sleeves, centering sleeves, and 2.0-mm Kirschner wires passed through the insertion guide. Results: The average distance from the superficial peroneal nerve to the center of holes 11, 12, and 13 was 10.0 mm (range 0-21, standard deviation 5.6), 6.8 mm (range 0-16, standard deviation 4.3), and 2.7 nun (0-11, standard deviation 3.7), respectively. In 12 of 14 legs (86%), the superficial peroneal nerve was 5.0 mm or less from the center of hole 13. The nerve was touching the guide wire at hole 11 in 1 specimen (7%), at hole 12 in 2 specimens (14%), and at hole 13 in 6 specimens (43%). In 1 specimen (7%), the guide wire pierced the superficial peroneal nerve at hole 13. Conclusion: These findings suggest that the superficial peroneal nerve is at significant risk during percutaneous screw placement in holes 11 through 13 of the 13-hole proximal tibia Less Invasive Stabilization System plate. Use of a larger incision and careful dissection down to the plate in this region may minimize the risk of damage to the nerve.
引用
收藏
页码:536 / 539
页数:4
相关论文
共 19 条
[1]
BAUMGAERTEL M, 1999, INJURY, V29, pC3
[2]
COLE PA, 2003, INJURY S1, V34, pSA16
[3]
Anatomic basis of vascularised nerve grafts:: the blood supply of peripheral nerves [J].
El-Barrany, WG ;
Marei, AG ;
Vallée, B .
SURGICAL AND RADIOLOGIC ANATOMY, 1999, 21 (02) :95-102
[4]
Minimally invasive plate osteosynthesis: Does percutaneous plating disrupt femoral blood supply less than the traditional technique? [J].
Farouk, O ;
Krettek, C ;
Miclau, T ;
Schandelmaier, P ;
Guy, P ;
Tscherne, H .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1999, 13 (06) :401-406
[5]
Farouk O, 1997, Injury, V28 Suppl 1, pA7, DOI 10.1016/S0020-1383(97)90110-8
[6]
Combined internal and external osteosynthesis - A biological approach to the treatment of complex fractures of the proximal tibia [J].
Gerber, A ;
Ganz, R .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1998, 29 :22-28
[7]
Distal femoral fracture fixation utilizing the Less Invasive Stabilization System (LISS): The technique and early results [J].
Kregor, PJ ;
Stannard, J ;
Zlowodzki, M ;
Cole, PA ;
Alonso, J .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2001, 32 :32-47
[8]
Krettek C, 1997, Injury, V28 Suppl 1, pA20, DOI 10.1016/S0020-1383(97)90112-1
[9]
KRETTEK C, 2001, INJURY, V32, pA4
[10]
*LISS, 2000, TECHN GUID PROX TIB