Emission behavior of formaldehyde and TVOC from engineered flooring in under heating and air circulation systems

被引:54
作者
An, Jae-Yoon [2 ]
Kim, Sumin [1 ]
Kim, Hyun-Joong [2 ,3 ]
Seo, Janghoo [4 ]
机构
[1] Soongsil Univ, Sch Architecture, Green Bldg Mat Lab, Seoul 156743, South Korea
[2] Seoul Natl Univ, Program Environm Mat Sci, Lab Adhes & Biocomposites, Seoul 151921, South Korea
[3] Seoul Natl Univ, Res Team Biomass Based Biomat, Res Inst Agr & Life Sci, Seoul 151921, South Korea
[4] Chosun Univ, Sch Architecture, Kwangju 501759, South Korea
关键词
Engineered flooring; Air circulation system; Floor heating system; VOCs; Formaldehyde; BUILDING FINISHING MATERIALS; WOOD-BASED COMPOSITES; VOC EMISSIONS; SMALL CHAMBER; RESINS; ONDOL;
D O I
10.1016/j.buildenv.2010.02.012
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Formaldehyde and volatile organic compounds (VOCs) from the adhesive, flooring, and flooring with adhesive were measured using a desiccator, a 20-L chamber and a field and laboratory emission cell (FLEC). Flooring with an adhesive is similar to that used in construction was applied to a floor heating system and an air circulation system, and the surface temperature of the flooring was set to 20 degrees C, 26 degrees C and 32 degrees C. The rate of formaldehyde emission from the flooring was the highest at 32 degrees C using a desiccator and decreased with time. The formaldehyde and aldehyde emissions from the samples using a 20-L chamber and FLEC showed a similar tendency. The VOCs emission trends with the 20-L chamber and FLEC were similar. The rate of formaldehyde and TVOC emission determined using FLEC was higher than that determined using the 20-L chamber method. The flooring emitted primarily benzene, toluene, ethylbenzene, styrene, xylene, as well as some unknown VOCs. There was a strong correlation between formaldehyde and TVOC emission for the 20-L chamber and FLEC. Samples using a floor heating system showed higher formaldehyde emission than those using an air circulation system. The level of TVOC emission was higher from the samples using an air circulation system than those using the floor heating system. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1826 / 1833
页数:8
相关论文
共 21 条
[1]  
AN JY, 2006, WOOD SCI TECHNOL, V34, P22
[2]  
[Anonymous], J ASIAN ARCHIT BUILD
[3]   Chamber assessment of formaldehyde and VOC emissions from wood-based panels [J].
Brown, SK .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1999, 9 (03) :209-215
[4]  
*JIS, 2001, A14602001 JIS JAP ST
[5]   Emission rates of formaldehyde from materials and consumer products found in California homes [J].
Kelly, TJ ;
Smith, DL ;
Satola, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1999, 33 (01) :81-88
[6]   Comparison of formaldehyde emission from building finishing materials at various temperatures in under heating system; ONDOL [J].
Kim, S ;
Kim, HJ .
INDOOR AIR, 2005, 15 (05) :317-325
[7]   Effect of addition of polyvinyl acetate to melamine-formaldehyde resin on the adhesion and formaldehyde emission in engineered flooring [J].
Kim, S ;
Kim, HJ .
INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2005, 25 (05) :456-461
[8]   Comparison of standard methods and gas chromatography method in determination of formaldehyde emission from MDF bonded with formaldehyde-based resins [J].
Kim, S ;
Kim, HJ .
BIORESOURCE TECHNOLOGY, 2005, 96 (13) :1457-1464
[9]   TVOC and formaldehyde emission behaviors from flooring materials bonded with environmental-friendly MF/PVAc hybrid resins [J].
Kim, Sumin ;
Kim, Jin-A. ;
An, Jae-Yoon ;
Kim, Hyun-Joong ;
Do Kim, Shin ;
Park, Jin Chul .
INDOOR AIR, 2007, 17 (05) :404-415
[10]   The effects of edge sealing treatment applied to wood-based composites on formaldehyde emission by desiccator test method [J].
Kim, Sumin ;
Kim, Jin-A ;
Kim, Hyun-Joong ;
Lee, Hwa Hyoung ;
Yoon, Dong-Won .
POLYMER TESTING, 2006, 25 (07) :904-911