Repeatability of ocular wavefront measurement

被引:34
作者
Davies, N
Diaz-Santana, L
Lara-Saucedo, D
机构
[1] City Univ London, Dept Optometry & Visual Sci, Appl Vis Res Ctr, London EC1V 0HB, England
[2] Middlesex Hosp, Dept Ophthalmol, London, England
[3] Univ London Imperial Coll Sci Technol & Med, Dept Phys, London, England
关键词
wavefront; refractive surgery; Zernike polynomial; cornea; error; custom correction;
D O I
10.1097/00006324-200302000-00010
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
Purpose. To assess the repeatability of measurements of ocular aberrations using wavefront sensing in a small group of observers and to assess the potential effect of measurement error on custom corneal correction due to this variability. Method A Shack-Hartmann wavefront sensor was used to measure the ocular wavefront in nine eyes. Head position was stabilized using a dental bite bar, and the pupil was centred using a cathode ray tube monitor and circular grating. Twenty Shack-Hartmann images were collected for each measurement. Each observer had three sets of measurements taken; the first and the second after careful alignment and the final after regrasping the bite bar in the same position as for the second measurement, but without pupil realignment. The modulation transfer functions for each set were calculated, and the effect of best-aligned custom treatments on the modulation transfer function was estimated. Results. There were highly statistically significant differences in a large number of Zernike modes between the three sets of measurements. The modulation transfer functions calculated for the residual wavefronts after aligned custom treatment were below the diffraction limit. The root mean square wavefront errors were consistently better for the residual wavefronts obtained using the realigned data than using data taken without pupil realignment. Conclusions. Sequential measurement of ocular aberrations shows statistically significant differences in a large number of Zernike modes. If aberrations determined by a single measurement are to be used in a custom correction, the resulting modulation transfer function is likely to remain below the diffraction limit. Pupil realignment is critical in reduction of the residual root mean square wavefront values to a minimum.
引用
收藏
页码:142 / 150
页数:9
相关论文
共 34 条
[1]
Dioptrics of the eye [J].
Ames, A ;
Proctor, CA .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1921, 5 :22-84
[2]
Applegate RA, 2000, J REFRACT SURG, V16, pS547
[3]
DIAZSANTANA L, 2000, THESIS IMPERIAL COLL
[4]
DIAZSANTANA L, 2000, 2 INT WORKSH AD OPT, P45
[5]
Closed-loop adaptive optics in the human eye [J].
Fernández, EJ ;
Iglesias, I ;
Artal, P .
OPTICS LETTERS, 2001, 26 (10) :746-748
[6]
Goodman W., 2005, INTRO FOURIER OPTICS, V3rd
[7]
Effect of rotation and translation on the expected benefit of an ideal method to correct the eye's higher-order aberrations [J].
Guirao, A ;
Williams, DR ;
Cox, IG .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2001, 18 (05) :1003-1015
[8]
Measurement of the wave-front aberration of the eye by a fast psychophysical procedure [J].
He, JC ;
Marcos, S ;
Webb, RH ;
Burns, SA .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1998, 15 (09) :2449-2456
[9]
Improvement in retinal image quality with dynamic correction of the eye's aberrations [J].
Hofer, H ;
Chen, L ;
Yoon, GY ;
Singer, B ;
Yamauchi, Y ;
Williams, DR .
OPTICS EXPRESS, 2001, 8 (11) :631-643
[10]
Dynamics of the eye's wave aberration [J].
Hofer, H ;
Artal, P ;
Singer, B ;
Aragón, JL ;
Williams, DR .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2001, 18 (03) :497-506