Feasibility of using a magnetic tracking device for measuring carpal kinematics

被引:17
作者
Ishikawa, J
Niebur, GL
Uchiyama, S
Linscheid, RL
Minami, A
Kaneda, K
An, KN
机构
[1] Mayo Clin & Mayo Fdn, Dept Orthoped, Biomech Lab, Rochester, MN 55905 USA
[2] Hokkaido Univ, Sch Med, Sapporo, Hokkaido 060, Japan
关键词
magnetic tracking; biplanar radiography; wrist; kinematics; accuracy;
D O I
10.1016/S0021-9290(97)00097-3
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
While several different methods have been used to measure carpal kinematics, biplanar radiography is generally considered to be the most accurate and popular one. However, biplanar radiography is tedious and so only pseudo-dynamic kinematics can be measured. Recently, magnetic tracking system has been developed for the measurement of joint kinematics which is versatile and easy to use and so the possibility of measuring motions dynamically. In this study, the capability of a magnetic tracking device to accurately measure carpal kinematics was investigated by comparing it with biplanar radiography. The kinematics of the third metacarpal, scaphoid, and lunate in five fresh cadaveric specimens were measured using both methods as the wrists were placed in eight positions. The finite screw rotation of each bone with respect to the distal radius during selecting the seven wrist motions was calculated for both measuring techniques and compared. In general, the kinematics for all three bones measured by using either magnetic tracking device or biplanar radiography was identical and showed no statistical difference. The averaged differences ranged from 0.0 to 2.0 degrees. These differences were due to the potential effect of the weight of the sensors and the interference of the attaching rod to the surrounding tissue. It is concluded that the application of the magnetic tracking device to carpal kinematics is warranted, if proper technical procedures as suggested are followed. (C) 1997 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1183 / 1186
页数:4
相关论文
共 22 条
[1]   APPLICATION OF A MAGNETIC TRACKING DEVICE TO KINESIOLOGIC STUDIES [J].
AN, KN ;
JACOBSEN, MC ;
BERGLUND, LJ ;
CHAO, EYS .
JOURNAL OF BIOMECHANICS, 1988, 21 (07) :613-&
[2]   KINEMATIC ANALYSIS OF HUMAN MOVEMENT [J].
AN, KN ;
CHAO, EY .
ANNALS OF BIOMEDICAL ENGINEERING, 1984, 12 (06) :585-597
[3]   BIOMECHANICAL INVESTIGATION OF WRIST KINEMATICS [J].
ANDREWS, JG ;
YOUM, Y .
JOURNAL OF BIOMECHANICS, 1979, 12 (01) :83-93
[4]  
BERGER RA, 1982, CLIN ORTHOP RELAT R, P303
[5]   AN INVIVO STUDY OF NORMAL WRIST KINEMATICS [J].
BRUMBAUGH, RB ;
CROWNINSHIELD, RD ;
BLAIR, WF ;
ANDREWS, JG .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1982, 104 (03) :176-181
[6]  
Bryce T H, 1896, J Anat Physiol, V31, P59
[7]   WRIST KINEMATICS AFTER LIMITED INTERCARPAL ARTHRODESIS [J].
GARCIAELIAS, M ;
COONEY, WP ;
AN, KN ;
LINSCHEID, RL ;
CHAO, EYS .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1989, 14A (05) :791-791
[8]   A KINEMATIC STUDY OF LUNO-TRIQUETRAL DISSOCIATIONS [J].
HORII, E ;
GARCIAELIAS, M ;
AN, KN ;
BISHOP, AT ;
COONEY, WP ;
LINSCHEID, RL ;
CHAO, EYS .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1991, 16A (02) :355-362
[9]   KINEMATICS OF THE TRAPEZIOMETACARPAL JOINT AFTER SECTIONING OF LIGAMENTS [J].
IMAEDA, T ;
NIEBUR, G ;
AN, KN ;
COONEY, WP .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1994, 12 (02) :205-210
[10]  
Itoi E, 1992, J Shoulder Elbow Surg, V1, P131, DOI 10.1016/1058-2746(92)90090-P