An interlaboratory study to find an alternative to the MPN technique for enumerating Escherichia coli in shellfish

被引:8
作者
Ogden, ID [1 ]
Brown, GC
Gallacher, S
Garthwaite, PH
Gennari, M
Gonzalez, MP
Jorgensen, LB
Lunestad, BT
MacRae, M
Nunes, MC
Petersen, AC
Rosnes, JT
Vliegenthart, J
机构
[1] Univ Aberdeen, Dept Med Microbiol, Aberdeen AB25 2ZD, Scotland
[2] Univ Aberdeen, Dept Math Sci, Aberdeen AB24 3QY, Scotland
[3] SOAEFD, Marine Lab, Aberdeen AB11 9DB, Scotland
[4] Inst Ispez Alimenti Origine Anim, Sez 1, I-20133 Milan, Italy
[5] Inst Invest Marinas, Vigo 36208, Spain
[6] MAF, Danish Inst Fisheries Res, DK-2800 Lyngby, Denmark
[7] Directorate Fisheries, Cent Lab, N-5002 Bergen, Norway
[8] Inst Portuques Invest Maritima, P-1400 Lisboa, Portugal
[9] Cork Reg Tech Coll, Cork, Ireland
[10] Norconserv, Inst Fish Proc & Preservat Technol, N-4001 Stavanger, Norway
[11] Inspectie Gezpndheidsbescherming, NL-4461 XN Goes, Netherlands
关键词
interlaboratory study; Escherichia coli; MPN; chromogenic media; conductance; shellfish;
D O I
10.1016/S0168-1605(98)00016-6
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Nine laboratories in eight countries tested 16 batches of common mussels (Mytilus edulis) over a 32 week period in order to find an alternative to the Most Probable Number (MPN) technique to enumerate E. coli. The alternatives investigated included the 3M Petrifilm system, the Merck Chromocult agar method and a Malthus conductance technique. The Petrifilm was found to be unsuitable and was subsequently dropped from the trial. After 669 analyses, a correlation of 0.83 was observed for log E. coli counts between the MPN and Chromocult methods and there was no significant evidence that either method tended to give higher readings than the other. The MPN was slightly better than the Chromocult method for repeatability but the Chromocult was slightly better for reproducibility. However, the observed differences an probably too small to be of practical importance. On the basis of these data therefore, the two methods appear equally suitable for E. coli enumeration in shellfish. There were poor correlations between these methods and the Malthus technique. A small but significant number of samples tested positive on the Malthus instrument but were recorded negative on the MPN and Chromocult tests. Subsequent analysis positively identified E. coli from these Malthus assays. After statistical analysis, errors were noted in both the MPN and Chromocult methods but it was found that there would be no statistical differences if the Chromocult agar were used as an alternative to the MPN technique. Published by Elsevier Science B.V.
引用
收藏
页码:57 / 64
页数:8
相关论文
共 7 条
[1]  
HOFSTRA H, 1988, J APPL BACT S S, pS197
[2]  
*ISO, 1981, 5725 ISO
[3]  
KILIAN M, 1976, ACTA PATH MICRO IM B, V84, P245
[4]  
MANAFI M, 1989, ZBL HYG UMWELTMED, V189, P225
[5]   AN EVALUATION OF FLUOROGENIC AND CHROMOGENIC ASSAYS FOR THE DIRECT ENUMERATION OF ESCHERICHIA-COLI [J].
OGDEN, ID ;
WATT, AJ .
LETTERS IN APPLIED MICROBIOLOGY, 1991, 13 (04) :212-215
[6]   A CONDUCTANCE ASSAY FOR THE DETECTION AND ENUMERATION OF ESCHERICHIA-COLI [J].
OGDEN, ID .
FOOD MICROBIOLOGY, 1993, 10 (04) :321-327
[7]  
*PHLS, 1992, PUBL HLTH LAB SERV M, V9, P76