Impact of creatinine calibration on performance of GFR estimating equations in a pooled individual patient database

被引:193
作者
Stevens, Lesley A.
Manzi, Jane
Levey, Andrew S.
Chen, Jing
Deysher, Amy E.
Greene, Tom
Poggio, Emilio D.
Schmid, Christopher H.
Steffes, Michael W.
Zhang, Yaping
Van Lente, Frederick
Coresh, Josef
机构
[1] Tufts Univ, New England Med Ctr, Div Nephrol, Boston, MA 02111 USA
[2] Johns Hopkins Univ, Baltimore, MD USA
[3] Tulane Univ, New Orleans, LA 70118 USA
[4] Univ Utah, Salt Lake City, UT USA
[5] Cleveland Clin, Cleveland, OH 44106 USA
[6] Univ Minnesota, Minneapolis, MN USA
关键词
chronic kidney disease; glomerular filtration rate; estimated glomerular filtration rate; calibration; creatinine; Modification of Diet in Renal Disease Study equation; Cockcroft-Gault equation; individual patient meta-analysis;
D O I
10.1053/j.ajkd.2007.04.004
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background: Variation in performance of glomerular filtration rate (GFR) estimating equations is related to variation in calibration of the creatinine assay across clinical laboratories. Study Design: Cross-sectional analysis. Setting & Participants: 6 research studies and 4 clinical populations including 5,504 participants who had GFR measured using urinary clearance of iothalamate. Measurements: Standardized serum creatinine values obtained by means of calibration to the Cleveland Clinic Research Laboratory using frozen specimens, a calibration panel, and/or survey results from the College of American Pathologists. Predictor: Noncalibrated serum creatinine assayed in research and clinical laboratories compared with standardized serum creatinine. Outcome: Difference between measured GFR versus GFR estimated from the Modification of Diet in Renal Disease (MDRD) Study and Cockcroft-Gault equations. Results: For a noncalibrated serum creatinine value of 1 mg/dL (88.4 mu mol/L), standardized serum creatinine value was 0.07 mg/dL (6.2 mu mol/L) less than noncalibrated values. In the pooled data set, for the MDRD Study equation, calibration improved median percentage of difference between measured and estimated GFR from 9.0% (interquartile range [IQR], 28%) to 5.8% (IQR, 28%) and improved the percentage of estimates within 30% of measured GFR (P-30) from 80% to 83%. The effect of calibration was greater at higher levels of GFR and varied across studies. For the Cockcroft-Gault equation, calibration worsened the median percentage of difference from -2.0% (IQR, 38%) to -11.4% (IQR, 39%), and the P-30 from 74% to 69%. Limitations: College of American Pathologist samples were used for calibration of clinical populations; calibration factors do not account for drift over time in the serum creatinine assay; calibration cannot account for variation in assay performance among individuals. Conclusion: Calibration improves the performance of the MDRD Study equation. After calibration, larger errors remain for GFR estimates greater than 60 mL/min/1.73 m(2) ( > 1 mL/s/1.73 m(2)).
引用
收藏
页码:21 / 35
页数:15
相关论文
共 40 条
  • [1] Chronic kidney disease and automatic reporting of estimated glomerular filtration rate: a position statement
    Anavekar, N
    Bais, R
    Carney, S
    Eris, J
    Gallagher, M
    Johnson, D
    Jones, G
    Sikaris, K
    Lonergan, M
    Ludlow, M
    Mackie, J
    Mathew, T
    May, S
    McBride, G
    Meerkin, M
    Peake, M
    Power, D
    Snelling, P
    Voss, D
    Walker, R
    [J]. MEDICAL JOURNAL OF AUSTRALIA, 2005, 183 (03) : 138 - +
  • [2] [Anonymous], 1999, C37A NCCLS
  • [3] *BRIT COL MIN HLTH, 2005, GUID PROT ADV COMM
  • [4] *CAISS NAT ASS MAL, 2004, AV CONV NAT DIR LAB
  • [5] Clase CM, 2002, J AM SOC NEPHROL, V13, P2812, DOI 10.1681/01.asn.0000926664.13303.f6
  • [6] Prevalence of low glomerular filtration rate in nondiabetic Americans: Third National Health and Nutrition Examination Survey (NHANES III)
    Clase, CM
    Garg, AX
    Kiberd, BA
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2002, 13 (05): : 1338 - 1349
  • [7] PREDICTION OF CREATININE CLEARANCE FROM SERUM CREATININE
    COCKCROFT, DW
    GAULT, MH
    [J]. NEPHRON, 1976, 16 (01) : 31 - 41
  • [8] Calibration and random variation of the serum creatinine assay as critical elements of using equations to estimate glomerular filtration rate
    Coresh, J
    Astor, BC
    McQuillan, G
    Kusek, J
    Greene, T
    Van Lente, F
    Levey, AS
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 2002, 39 (05) : 920 - 929
  • [9] Estimating the prevalence of low glomerular filtration rate requires attention to the creatinine assay calibration
    Coresh, J
    Eknoyan, G
    Levey, AS
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2002, 13 (11): : 2811 - 2812
  • [10] Kidney function estimating equations: where do we stand?
    Coresh, Josef
    Stevens, L. A.
    [J]. CURRENT OPINION IN NEPHROLOGY AND HYPERTENSION, 2006, 15 (03) : 276 - 284