Prevention of aluminium exposure through dialysis fluids. Analysis of changes in the last 8 years

被引:25
作者
Fernandez-Martin, JL [1 ]
Canteros, A [1 ]
Serrano, M [1 ]
Gonzalez-Carcedo, A [1 ]
Diaz-Corte, C [1 ]
Andia, JBC [1 ]
机构
[1] Hosp Cent Asturias, Inst Reine Sofia Invest, Bone & Mineral Res Unit, E-33006 Oviedo, Asturias, Spain
关键词
aluminium exposure; dialysis fluid; haemodialysis; quality of dialysis;
D O I
10.1093/ndt/13.suppl_3.78
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Despite extensive measures to control aluminium exposure, chronic and acute episodes of aluminium intoxication still occur. The objective of this study was to analyse the changes in the aluminium content of dialysis fluid and the effect on serum aluminium in different dialysis centres in Spain in the last 8 years. For this purpose, the aluminium content in dialysis fluid and serum samples (N = 5609) from 17 dialysis centres was analysed for >8 years (from the last quarter of 1988 to 1996). In that period of time, the percentage of dialysis fluid samples with acceptable concentrations of aluminium (<2 mu g/l) increased from 0% in 1988 to 80% in 1996. The percentage of dialysis fluid samples with high aluminium levels (>6 mu g/l) ranged between 37.5% in 1988 and 2.3% in 1996. The improvement in the quality of the dialysis fluid resulted in lower values of serum aluminium. The percentage of serum samples with low aluminium (<20 mu g/l) increased from 16.5% in 1988 to 54.2% in 1966. The mean serum aluminium correlated with the mean dialysis fluid aluminium (r=0.55, P<0.001). A higher correlation was found when the aluminium in dialysis fluid ranged between 4 and 10 mu g/l (r=0.802, P<0.001), and no correlation was found when the aluminium in dialysis fluid was <4 mu g/l. Even taking into account that the dialysis fluid is not the only source of aluminium for dialysis patients, our study clearly demonstrated a close relationship with the serum aluminium content. Therefore, we must emphasize the necessity for controlling the aluminium content in dialysis fluid more often than is done at present.
引用
收藏
页码:78 / 81
页数:4
相关论文
共 23 条
[1]  
Alfrey A C, 1993, Contrib Nephrol, V102, P110
[2]  
ANDIA JBC, 1989, REV CLIN ESP, V184, P371
[3]  
Barata JD, 1996, NEPHROL DIAL TRANSPL, V11, P125
[4]   EPIDEMIC ALUMINUM INTOXICATION IN HEMODIALYSIS-PATIENTS TRACED TO USE OF AN ALUMINUM PUMP [J].
BURWEN, DR ;
OLSEN, SM ;
BLAND, LA ;
ARDUINO, MJ ;
REID, MH ;
JARVIS, WR .
KIDNEY INTERNATIONAL, 1995, 48 (02) :469-474
[5]  
CANNATA JB, 1983, LANCET, V1, P501
[6]  
CANNATA JB, 1997, IN PRESS KIDNEY INT
[7]  
Cannata JB, 1994, LIVE CHEM REPORT, V11, P207
[8]  
CANNATA JB, 1989, ALUMINIUM RENAL FAIL, V26, P287
[9]   MECHANISMS OF ALUMINUM-INDUCED MICROCYTOSIS - LESSONS FROM ACCIDENTAL ALUMINUM INTOXICATION [J].
CARAMELO, CA ;
CANNATA, JB ;
RODELES, MR ;
MARTIN, JLF ;
MOSQUERA, JR ;
MONZU, B ;
OUTEIRINO, J ;
BLUM, G ;
ANDREA, C ;
FARRE, AJL ;
ACUNA, G ;
CASADO, S ;
HERNANDO, L .
KIDNEY INTERNATIONAL, 1995, 47 (01) :164-168
[10]  
DOUTHAT W, 1994, NEFROLOGIA, V14, P695