Bone marrow biopsy morbidity and mortality: 2002 data
被引:53
作者:
Bain, BJ
论文数: 0引用数: 0
h-index: 0
机构:
Univ London Imperial Coll Sci & Technol, Fac Med, Dept Haematol, London W2 1NY, EnglandUniv London Imperial Coll Sci & Technol, Fac Med, Dept Haematol, London W2 1NY, England
Bain, BJ
[1
]
机构:
[1] Univ London Imperial Coll Sci & Technol, Fac Med, Dept Haematol, London W2 1NY, England
来源:
CLINICAL AND LABORATORY HAEMATOLOGY
|
2004年
/
26卷
/
05期
关键词:
bone marrow aspiration;
bone marrow trephine biopsy;
complications;
D O I:
10.1111/j.1365-2257.2004.00630.x
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
A survey of morbidity and mortality of bone marrow aspiration and trephine biopsy was carried out for the British Society of Haematology, covering the 12 months of 2002. Fifty-three centres reported 13 506 procedures, comprising 3927 aspiration biopsies and 9579 combined procedures. There were 17 adverse events including nine instances of haemorrhage, four infections and one haemorrhage complicated by infection. Two trephine biopsy needles broke during the procedure. One patient suffered considerable pain for 2 weeks. The adverse event may have contributed to death in two patients and in a third patient was life-threatening. Risk factors for adverse events were identified.