Sensitive high-resolution analysis of biological molecules by capillary zone electrophoresis coupled with reflecting time-of-flight mass spectrometry

被引:38
作者
McComb, ME
Krutchinsky, AN
Ens, W
Standing, KG
Perreault, H [1 ]
机构
[1] Univ Manitoba, Dept Chem, Winnipeg, MB R3T 2N2, Canada
[2] Univ Manitoba, Dept Phys, Winnipeg, MB R3T 2N2, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
capillary electrophoresis mass spectrometry; interfaces; CE-MS; electrospray ionization; detection; electrophoresis; peptides; proteins;
D O I
10.1016/S0021-9673(97)01158-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Off-line and on line capillary zone electrophoresis-electrospray ionization time-of-flight mass spectrometry (CZE-ESI-TOF-MS) experiments were conducted using uncoated fused-silica capillaries coupled to a reflecting TOF mass spectrometer via a gold-coated sheathless interface. Off-line and on-line experiments were performed on standard mixtures of proteins and peptides. Samples collected off-line electrokinetically in plastic vials were analyzed by standard ESI-TOF-MS at the pmol level. Sheathless CZE-ESI-TOF-MS was first simulated in an off-line experiment, using a test bench, in order to select a suitable running electrolyte, to find the optimal electrospray potential, and also to test the gold-coated capillary tips. This enabled an ease of transition to on-line measurements. On-line CZE-ESI-TOF-MS measurements of the total ion electropherogram (TIE) and of selected ion electropherograms (SIE) on peptide mixtures demonstrated fmol-level sensitivity, with S/N values of 250-400 on raw data (TIE mode) and of 30-760 (SIE mode). The use of reflecting TOF-MS afforded mass resolution values R>6000 (m/Delta m(FWHM)) and enabled isotopic resolution of peptide components as well as mass accuracy in the 10 ppm range. These results were comparable with values observed with the usual ESI source on the same mass spectrometer, and thus demonstrated no loss in spectral quality from using the sheathless CE interface. On-line CE separation efficiency was equivalent to that obtained off-line for the separation of a peptide mixture, with N=35000-87000 theoretical plates. Separations of standard proteins yielded equivalent mass spectral resolution and accuracy with separation efficiencies of N=2800-5500 and S/N values of 110-225 on raw data. The gold-coated sheathless CE-ESI interface was found to be relatively easy to prepare with the use of gold vapour deposition. The interface produced a stable electrospray for extended periods of time and was found to be robust and reliable. (C) Elsevier Science B.V.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 27 条
[1]   Detection of fast capillary electrophoresis peptide and protein separations using electrospray ionization with a time-of-flight mass spectrometer [J].
Banks, JF ;
Dresch, T .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1480-1485
[2]  
Bateman KP, 1997, RAPID COMMUN MASS SP, V11, P307
[3]  
BRUIN GJM, 1995, ANAL METHOD INSTRUM, V2, P3
[4]   CAPILLARY ELECTROPHORESIS MASS-SPECTROMETRY [J].
CAI, JY ;
HENION, J .
JOURNAL OF CHROMATOGRAPHY A, 1995, 703 (1-2) :667-692
[5]  
CHERNUSHEVICH IV, 1997, ELECTROSPRAY IONIZAT, P203
[6]   ONLINE TIME-OF-FLIGHT MASS-SPECTROMETRIC ANALYSIS OF PEPTIDES SEPARATED BY CAPILLARY ELECTROPHORESIS [J].
FANG, LL ;
ZHANG, R ;
WILLIAMS, ER ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1994, 66 (21) :3696-3701
[7]   TOTAL CHEMICAL SYNTHESIS AND CATALYTIC PROPERTIES OF THE ENZYME ENANTIOMERS L-4-OXALOCROTONATE AND D-4-OXALOCROTONATE TAUTOMERASE [J].
FITZGERALD, MC ;
CHERNUSHEVICH, I ;
STANDING, KG ;
KENT, SBH ;
WHITMAN, CP .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1995, 117 (45) :11075-11080
[8]   Probing the oligomeric structure of an enzyme by electrospray ionization time-of-flight mass spectrometry [J].
Fitzgerald, MC ;
Chernushevich, I ;
Standing, KG ;
Whitman, CP ;
Kent, SBH .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1996, 93 (14) :6851-6856
[9]   LIQUID SHEATH EFFECTS ON THE SEPARATION OF PROTEINS IN CAPILLARY ELECTROPHORESIS ELECTROSPRAY MASS-SPECTROMETRY [J].
FORET, F ;
THOMPSON, TJ ;
VOUROS, P ;
KARGER, BL ;
GEBAUER, P ;
BOCEK, P .
ANALYTICAL CHEMISTRY, 1994, 66 (24) :4450-4458
[10]   MATRIX-ASSISTED LASER DESORPTION MASS-SPECTROMETRY OF PROTEINS ISOLATED BY CAPILLARY ZONE ELECTROPHORESIS [J].
KEOUGH, T ;
TAKIGIKU, R ;
LACEY, MP ;
PURDON, M .
ANALYTICAL CHEMISTRY, 1992, 64 (14) :1594-1600