Influence of convolution filtering on coronary plaque attenuation values: observations in an ex vivo model of multislice computed tomography coronary angiography

被引:55
作者
Cademartiri, Filippo
La Grutta, Ludovico
Runza, Giuseppe
Palumbo, Alessandro
Maffei, Erica
Mollet, Nico R. A.
Bartolotta, Tommaso Vincenzo
Somers, Pamela
Knaapen, Michiel
Verheye, Stefan
Midiri, Massimo
Hamers, Ronald
Bruining, Nico
机构
[1] Erasmus MC, Dept Radiol, NL-3015 GD Rotterdam, Netherlands
[2] Erasmus MC, Dept Cardiol, NL-3015 GD Rotterdam, Netherlands
[3] Univ Parma, Azienda Osped, Dept Radiol, I-43100 Parma, Italy
[4] Univ Parma, Azienda Osped, Dept Cardiol, I-43100 Parma, Italy
[5] Univ Palermo, Dept Radiol, DIBIMEL, Palermo, Italy
[6] Middelheim Hosp, Dept Pathol, Antwerp, Belgium
[7] Middelheim Hosp, Dept Cardiol, Antwerp, Belgium
关键词
multislice computed tomography; coronary angiography; coronary plaque; convolutions kernels;
D O I
10.1007/s00330-006-0548-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Attenuation variability ( measured in Hounsfield Units, HU) of human coronary plaques using multislice computed tomography (MSCT) was evaluated in an ex vivo model with increasing convolution kernels. MSCT was performed in seven ex vivo left coronary arteries sunk into oil followingthe instillation of saline (1/infinity) and a 1/50 solution of contrast material ( 400 mgI/ml iomeprol). Scan parameters were: slices/ collimation, 16/0.75 mm; rotation time, 375 ms. Four convolution kernels were used: b30f-smooth, b36f-medium smooth, b46f-medium and b60f-sharp. An experienced radiologist scored for the presence of plaques and measured the attenuation in lumen, calcified and noncalcified plaques and the surrounding oil. The results were compared by the ANOVA test and correlated with Pearson's test. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. The mean attenuation values were significantly different between the four filters ( p < 0.0001) in each structure with both solutions. After clustering for the filter, all of the noncalcified plaque values (20.8 +/- 39.1, 14.2 +/- 35.8, 14.0 +/- 32.0, 3.2 +/- 32.4 HU with saline; 74.7 +/- 66.6, 68.2 +/- 63.3, 66.3 +/- 66.5, 48.5 +/- 60.0 HU in contrast solution) were significantly different, with the exception of the pair b36f - b46f, for which a moderate-high correlation was generally found. Improved SNRs and CNRs were achieved by b30f and b46f. The use of different convolution filters significantly modifief the attenuation values, while sharper filtering increased the calcified plaque attenuation and reduced the noncalcified plaque attenuation.
引用
收藏
页码:1842 / 1849
页数:8
相关论文
共 31 条
[1]   Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography - A segment-based comparison with intravascular ultrasound [J].
Achenbach, S ;
Moselewski, F ;
Ropers, D ;
Ferencik, M ;
Hoffmann, U ;
MacNeill, B ;
Pohle, K ;
Baum, U ;
Anders, K ;
Jang, I ;
Daniel, WG ;
Brady, TJ .
CIRCULATION, 2004, 109 (01) :14-17
[2]   Ex vivo coronary atherosclerotic plaque characterization with multi-detector-row CT [J].
Becker, CR ;
Nikolaou, K ;
Muders, M ;
Babaryka, G ;
Crispin, A ;
Schoepf, UJ ;
Loehrs, U ;
Reiser, MF .
EUROPEAN RADIOLOGY, 2003, 13 (09) :2094-2098
[3]  
Botnar RM, 2000, CIRCULATION, V102, P2582
[4]   ACCF/AHA clinical competence statement on cardiac imaging with computed tomography and magnetic resonance - A report of the American College of Cardiology Foundation/American Heart Association/American college of Physicians Task Force on clinical competence and training [J].
Budoff, MJ ;
Cohen, MC ;
Garcia, MJ ;
Hodgson, JM ;
Hundley, WG ;
Lima, JAC ;
Manning, WJ ;
Pohost, GM ;
Raggi, PM ;
Rodgers, GP ;
Rumberger, JA ;
Taylor, AJ ;
Creager, MA ;
Hirshfeld, JW ;
Lorell, BH ;
Merli, G ;
Rodgers, GP ;
Tracy, CM ;
Weitz, HH .
CIRCULATION, 2005, 112 (04) :598-617
[5]   Influence of intracoronary attenuation on coronary plaque measurements using multislice computed tomography: observations in an ex vivo model of coronary computed tomography angiography [J].
Cademartiri, F ;
Mollet, NR ;
Runza, G ;
Bruining, N ;
Hamers, R ;
Somers, P ;
Knaapen, M ;
Verheye, S ;
Midiri, M ;
Krestin, GP ;
de Feyter, PJ .
EUROPEAN RADIOLOGY, 2005, 15 (07) :1426-1431
[6]   In vitro characterization of atherosclerotic carotid plaque with multidetector computed tomography and histopathological correlation [J].
de Weert, TT ;
Ouhlous, M ;
Zondervan, P ;
Hendriks, JM ;
Dippel, DWJ ;
van Sambeek, MRHM ;
van der Lugt, A .
EUROPEAN RADIOLOGY, 2005, 15 (09) :1906-1914
[7]  
Fayad ZA, 2000, CIRCULATION, V102, P506
[8]   First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[9]   MECHANISMS OF DISEASE - THE PATHOGENESIS OF CORONARY-ARTERY DISEASE AND THE ACUTE CORONARY SYNDROMES .1. [J].
FUSTER, V ;
BADIMON, L ;
BADIMON, JJ ;
CHESEBRO, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 1992, 326 (04) :242-250
[10]  
FUSTER V, 1992, NEW ENGL J MED, V326, P310