Validation and comparative analysis of a multiplexed assay for the simultaneous quantitative measurement of Th1/Th2 cytokines in human serum and human peripheral blood mononuclear cell culture supernatants

被引:66
作者
Prabhakar, U [1 ]
Eirikis, E [1 ]
Reddy, M [1 ]
Silvestro, E [1 ]
Spitz, S [1 ]
Pendley, C [1 ]
Davis, HM [1 ]
Miller, BE [1 ]
机构
[1] Centocor Inc, Dept Clin Pharmacol, Malvern, PA 19355 USA
关键词
multiplexed; PBMCs; Th1/Th2; cytokines; serum; culture supernatant;
D O I
10.1016/j.jim.2004.04.018
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
There is increasing evidence suggesting a relationship between cytokine levels and disease pathogenesis, which has led to interest in analyzing multiple cytokines in biological fluids and culture supernatants for various research and clinical studies. The introduction of methodologies allowing simultaneous measurement of interrelated biomarkers/cytokines has further revolutionized this process. In contrast to tissue culture supernatant, the measurement of cytokines in serum has proven to be difficult to characterize in multiplexed formats because of the presence of large dynamic concentration ranges of proteins and other interfering factors that are present in this matrix. In the present study, we have used the microsphere-based multiplex method to simultaneously quantitate and compare six analytes, encompassing a representation of the Th1/Th2 cytokine panel (interleukin (IL)-2, IL-4, IL-5, interferon-gamma, (IFN-gamma), tumor necrosis factor-alpha (TNF-alpha), and IL-10), in both serum and culture supernatants from peripheral blood mononuclear cells (PBMCs). A detailed validation procedure for these determinations is described along with a comparative analysis of the performance of the multiplexed assay in serum and culture supernatant matrices. Our results indicate that precision of the multiplexed assay is comparable in both culture supernatant and serum. However, the accuracy of quantification of cytokines in the serum matrix but not in culture supernatant may be compromised depending upon the cytokine being analyzed. Therefore, one must use caution when interpreting data from such complex matrices. Nevertheless, this assay format is appropriate to profile cytokines in clinical trial samples. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:27 / 38
页数:12
相关论文
共 23 条
[1]  
BOYUM A, 1968, SCAND J CLIN LAB I S, V97, P21
[2]   Flow cytometric microsphere-based immunoassay:: Analysis of secreted ctytokines in whole-blood samples from asthmatics [J].
Camilla, C ;
Mély, L ;
Magnan, A ;
Casano, B ;
Prato, S ;
Debono, S ;
Montero, F ;
Defoort, JP ;
Martin, M ;
Fert, V .
CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2001, 8 (04) :776-784
[3]   Simultaneous quantitation of 15 cytokines using a multiplexed flow cytometric assay [J].
Carson, RT ;
Vignali, DAA .
JOURNAL OF IMMUNOLOGICAL METHODS, 1999, 227 (1-2) :41-52
[4]  
Chen R, 1999, CLIN CHEM, V45, P1693
[5]   Simultaneous measurement of six cytokines in a single sample of human tears using microparticle-based flow cytometry, allergies vs. non-allergies [J].
Cook, EB ;
Stahl, JL ;
Lowe, L ;
Chen, R ;
Morgan, E ;
Wilson, J ;
Varro, R ;
Chan, A ;
Graziano, FM ;
Barney, NP .
JOURNAL OF IMMUNOLOGICAL METHODS, 2001, 254 (1-2) :109-118
[6]   Graft-versus-host disease: The influence of type 1 and type 2 T cell cytokines [J].
Ferrara, JLM ;
Krenger, W .
TRANSFUSION MEDICINE REVIEWS, 1998, 12 (01) :1-17
[7]   Cytokines and the regulation of tolerance [J].
Ferrara, JLM .
JOURNAL OF CLINICAL INVESTIGATION, 2000, 105 (08) :1043-1044
[8]   ROLE OF THE CD28 RECEPTOR IN T-CELL ACTIVATION [J].
JUNE, CH ;
LEDBETTER, JA ;
LINSLEY, PS ;
THOMPSON, CB .
IMMUNOLOGY TODAY, 1990, 11 (06) :211-216
[9]   Expression of Th1 markers by lung accumulated T cells in pulmonary sarcoidosis [J].
Katchar, K ;
Eklund, A ;
Grunewald, J .
JOURNAL OF INTERNAL MEDICINE, 2003, 254 (06) :564-571
[10]  
Kellar KL, 2001, CYTOMETRY, V45, P27, DOI 10.1002/1097-0320(20010901)45:1<27::AID-CYTO1141>3.0.CO