Physiological axial compressive preloads increase motion segment stiffness, linearity and hysteresis in all six degrees of freedom for small displacements about the neutral posture

被引:89
作者
Gardner-Morse, MG [1 ]
Stokes, IA [1 ]
机构
[1] Univ Vermont, Dept Orthopaed & Rehabil, Burlington, VT 05405 USA
关键词
biomechanics; lumbar spine; stiffness; axial compressive preload; hysteresis; linearity;
D O I
10.1016/S0736-0266(02)00199-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The stiffness of motion segments, together with muscle actions, stabilizes the spinal column. The objective of this study was to compare the experimentally measured load-displacement behavior of porcine lumbar motion segments in vitro with physiological axial compressive preloads of 0, 200 and 400 N equilibrated in a physiological fluid environment, for small displacements about the neutral posture. These preloads are hypothesized to increase stiffness, hysteresis and linearity of the load-displacement behavior. At each preload, displacements in each of six degrees of freedom (+/-0.3 mm AP and lateral translations, +/-0.2 mm axial translation, +/-1degrees lateral bending and +/-0.8degrees flexion/extension and torsional rotations) were imposed. The resulting forces and moments were recorded. Tests were repeated after removal of posterior elements. Using least squares, the forces at the vertebral body center were related to the displacements by a symmetric 6 x 6 stiffness matrix. Six diagonal and two off-diagonal load-displacement relationships were examined for differences in stiffness, linearity and hysteresis in each testing condition. Mean values of the diagonal terms of the stiffness matrix for intact porcine motion segments increased significantly by an average factor of 2.2 and 2.9 with 200 and 400 N axial compression respectively (p < 0.001). Increases for isolated disc specimens averaged 4.6 and 6.9 times with 200 and 400 N preload (p < 0.001). Changes in hysteresis correlated with the changes in stiffness. The load-displacement relationships were progressively more linear with increasing preload (R-2 = 0.82, 0.97 and 0.98 at 0, 200 and 400 N axial compression respectively). Motion segment and disc load-displacement behaviors were stiffer, more linear and had greater hysteresis with axial compressive preloads. (C) 2002 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:547 / 552
页数:6
相关论文
共 21 条
[1]  
Bergmark A, 1989, Acta Orthop Scand Suppl, V230, P1
[2]   ON THE MECHANICAL-BEHAVIOR OF INTERVERTEBRAL DISKS [J].
BROBERG, KB .
SPINE, 1983, 8 (02) :151-165
[3]   Mechanical stability of the in vivo lumbar spine: Implications for injury and chronic low back pain [J].
Cholewicki, J ;
McGill, SM .
CLINICAL BIOMECHANICS, 1996, 11 (01) :1-15
[4]   In vitro axial preload application during spine flexibility testing: towards reduced apparatus-related artefacts [J].
Cripton, PA ;
Bruehlmann, SB ;
Orr, TE ;
Oxland, TR ;
Nolte, LP .
JOURNAL OF BIOMECHANICS, 2000, 33 (12) :1559-1568
[5]   VARIATION OF LUMBAR SPINE STIFFNESS WITH LOAD [J].
EDWARDS, WT ;
HAYES, WC ;
POSNER, I ;
WHITE, AA ;
MANN, RW .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1987, 109 (01) :35-41
[6]   ROLE OF MUSCLES IN LUMBAR SPINE STABILITY IN MAXIMUM EXTENSION EFFORTS [J].
GARDNERMORSE, M ;
STOKES, IAF ;
LAIBLE, JP .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1995, 13 (05) :802-808
[7]   3-DIMENSIONAL MOTION BEHAVIOR OF THE HUMAN SPINE - A QUESTION OF TERMINOLOGY [J].
GOEL, VK .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1987, 109 (04) :353-355
[8]  
HAUERSTOCK D, 2001, T 47 ANN M ORTH RES
[9]   The viscoelastic behavior of the non-degenerate human lumbar nucleus pulposus in shear [J].
Iatridis, JC ;
Setton, LA ;
Weidenbaum, M ;
Mow, VC .
JOURNAL OF BIOMECHANICS, 1997, 30 (10) :1005-1013
[10]   LARGE COMPRESSIVE PRELOADS DECREASE LUMBAR MOTION SEGMENT FLEXIBILITY [J].
JANEVIC, J ;
ASHTONMILLER, JA ;
SCHULTZ, AB .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (02) :228-236