Distance Protection of Lines Connected to Induction Generator-Based Wind Farms During Balanced Faults

被引:148
作者
Hooshyar, Ali [1 ]
Abdelkhalek, Maher [1 ]
El-Saadany, Ehab F. [1 ]
机构
[1] Univ Waterloo, Dept Elect & Comp Engn, Waterloo, ON N2L 3G1, Canada
关键词
Distance relay; doubly fed induction generator (IG); squirrel cage induction generator (SCIG); wind farm (WF); SYSTEMS;
D O I
10.1109/TSTE.2014.2336773
中图分类号
X [环境科学、安全科学];
学科分类号
083001 [环境科学];
摘要
Wind farms (WFs) are increasingly integrated with high-voltage (HV) grids, for which distance relaying is normally the protection of choice. This paper reveals some serious defects of distance protection for the lines connected to induction generator (IG)-based WFs during balanced faults. It is shown that for the squirrel cage IG (SCIG) WFs, distance protection becomes insecure, while for the doubly fed IG (DFIG) WFs, the relay performance is utterly unreliable, due to operating scenarios that are unique to such WFs, and are unfamiliar to the existing relaying practices. The detected failures can easily result in unnecessary WF tripping, thus jeopardizing the objectives pursued by the new grid codes that oblige WFs to remain connected to the grid during disturbances. Moreover, a novel modified permissive overreach transfer trip (POTT) scheme along with a fault current classification technique is proposed to address these problems for both types of IG-based WFs, and the accurate nondelayed protection of a distance relay over the entire line length is restored. A comprehensive performance evaluation confirms the findings of this paper and validates the efficacy of the proposed solution for all operating conditions. Results are particularly promising for the DFIG-based WFs with nonzero crowbar resistance, which is the most likely situation confronted by distance relays.
引用
收藏
页码:1193 / 1203
页数:11
相关论文
共 28 条
[1]
Ackermann T., 2012, WIND POWER POWER SYS
[2]
Anderson P. M., 1995, ANAL FAULTED POWER S
[3]
[Anonymous], 2012, Instruction Manual: SUPRA VP series: Variable pressure field emission scanning electron microscopes
[4]
[Anonymous], 2012, Instruction Manual for SEL-321-3,-4: Distance and Directional Overcurrent Relay, Patent No. 5721689
[5]
[Anonymous], 1999, C371131999 IEEE
[6]
[Anonymous], 2003, SEL 700GW WIND GENER
[7]
Blackburn J. L., 2006, PROTECTIVE RELAYING
[8]
Overview of Control Systems for the Operation of DFIGs in Wind Energy Applications [J].
Cardenas, Roberto ;
Pena, Ruben ;
Alepuz, Salvador ;
Asher, Greg .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (07) :2776-2798
[9]
Clark Kara., 2008, MODELING GE WIND TUR
[10]
APPLICATION OF TEST RESULTS TO CALCULATION OF SHORT-CIRCUIT LEVELS IN LARGE INDUSTRIAL SYSTEMS WITH CONCENTRATED INDUCTION-MOTOR LOADS [J].
COOPER, CB ;
MACLEAN, DM ;
WILLIAMS, KG .
PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1969, 116 (11) :1900-&