Biomechanical comparison of plate-screw and screw fixation in medial tibial plateau fractures (Schatzker 4). A model study

被引:35
作者
Cift, H. [1 ]
Cetik, O. [2 ]
Kalaycioglu, B. [3 ]
Dirikoglu, M. H. [3 ]
Ozkan, K. [1 ]
Eksioglu, F. [2 ]
机构
[1] Goztepe Training & Res Hosp, Dept Orthopaed & Traumatol, Istanbul, Turkey
[2] Kirikkale Univ, Dept Orthopaed & Traumatol, TR-71451 Kirikkale, Turkey
[3] Kirikkale Univ, Dept Mech Engn, TR-71451 Kirikkale, Turkey
关键词
Medial tibial plateau fractures; Bone model; Fixation;
D O I
10.1016/j.otsr.2009.11.016
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Introduction: The objective of this biomechanical study was to compare the respective efficiency of plate-screw fixation and screw fixation in an experimental model of a Schatzker type 4 fracture. Hypothesis: screw fixation and plate fixation have a similar load to failure. Materials and methods: This study compares the stability of Schatzker type 4 medial tibial plateau fractures fixed with either 36.5mm cancellous bone screw with a 16mm threaded segment or with six-holed buttress T-plate-screw system. A Schatzker type 4 fracture was modeled on an artificial bone model. In a first group of 10 fracture models, following the anatomical reduction, fractures were stabilized with screws with washers. In the second group, of 10 fracture models, fractures were stabilized with T-plate. After fixation ascending axial compression was applied on bone models (Instron machine). Results: Load bearing capacity was 1397.6 +/- 194.4 N in the Group 1 and 2153.2 +/- 204.4 N in the Group 2. The difference between the two groups was statistically significant (p < 0.001). Discussion: According to this result, experimental load bearing of bone models indicate that plate-screw fixation system has a significantly higher stabilization capacity than fixation with three screws alone. Our hypothesis was not confirmed. In order to maintain anatomical repositioning, plate-screw system is a more stable fixation method than the screw in medial tibial plateau fractures Schatzker 4 Level of evidence: 1. (C) 2010 Published by Elsevier Masson SAS.
引用
收藏
页码:263 / 267
页数:5
相关论文
共 17 条
[1]
Experimental model of tibial plateau fracture for biomechanical testing [J].
Ali, Ahmad M. ;
Saleh, Michael ;
Bolongaro, Stefano ;
Yang, Lang .
JOURNAL OF BIOMECHANICS, 2006, 39 (07) :1355-1360
[2]
Benirschke S K, 1992, J Orthop Trauma, V6, P78
[3]
Boisrenoult P, 2000, REV CHIR ORTHOP, V86, P707
[4]
Boszotta H, 1993, Aktuelle Traumatol, V23, P178
[5]
BOWES DN, 1982, CLIN ORTHOP RELAT R, P104
[6]
HSU RWW, 1990, CLIN ORTHOP RELAT R, P215
[7]
TIBIAL PLATEAU FRACTURES - A COMPARISON OF CONSERVATIVE AND SURGICAL-TREATMENT [J].
JENSEN, DB ;
RUDE, C ;
DUUS, B ;
BJERGNIELSEN, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (01) :49-52
[8]
LACHIEWICZ PF, 1990, CLIN ORTHOP RELAT R, P210
[9]
Levy Ofer, 1993, Bulletin Hospital for Joint Diseases, V53, P15
[10]
Arthroscopic management of tibial plateau fractures [J].
Lubowitz, JH ;
Elson, WS ;
Guttmann, D .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2004, 20 (10) :1063-1070