Recent developments in the field of screen-printed electrodes and their related applications

被引:602
作者
Dominguez Renedo, O. [1 ]
Alonso-Lomillo, M. A. [1 ]
Arcos Martinez, M. J. [1 ]
机构
[1] Univ Burgos, Fac Sci, Dept Chem, Burgos 09001, Spain
关键词
screen-printed electrodes; review; film-modified sensors; biosensors; immunosensors; electrochemistry;
D O I
10.1016/j.talanta.2007.03.050
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
The development of analytical methods that respond to the growing need to perform rapid 'in situ' analyses shows disposable screen-printed electrodes (SPEs) as an alternative to the traditional electrodes. This review presents recent developments in the electrochemical application of disposable screen-printed sensors, according to the types of materials used to modify the working electrode. Therefore, unmodified SPE, film-modified SPE, enzyme-modified SPE and antigen/antibody-modified SPE are described. Applications are included where available. (C) 2007 Elsevier B.V All rights reserved.
引用
收藏
页码:202 / 219
页数:18
相关论文
共 218 条
[1]
Monoclonal antibody based electrochemical immunosensor for the determination of ochratoxin A in wheat [J].
Alarcon, Sergio Hugo ;
Palleschi, Giuseppe ;
Compagnone, Dario ;
Pascale, Michelangelo ;
Visconti, Angelo ;
Barna-Vetro, Ildiko .
TALANTA, 2006, 69 (04) :1031-1037
[2]
Development of an electrochemical immunosensor for ochratoxin A [J].
Alarcón, SH ;
Micheli, L ;
Palleschi, G ;
Compagnone, D .
ANALYTICAL LETTERS, 2004, 37 (08) :1545-1558
[3]
Alvarez MJB, 2002, ANAL CHIM ACTA, V462, P31
[4]
Enzyme inhibition-based biosensors for food safety and environmental monitoring [J].
Amine, A ;
Mohammadi, H ;
Bourais, I ;
Palleschi, G .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (08) :1405-1423
[5]
Detection of aflatoxin B1 in barley:: Comparative study of immunosensor and HPLC [J].
Ammida, N. H. S. ;
Micheli, L. ;
Piermarini, S. ;
Moscone, D. ;
Palleschi, G. .
ANALYTICAL LETTERS, 2006, 39 (08) :1559-1572
[6]
Electrochemical immunosensor for determination of aflatoxin B1 in barley [J].
Ammida, NHS ;
Micheli, L ;
Palleschi, G .
ANALYTICA CHIMICA ACTA, 2004, 520 (1-2) :159-164
[7]
Ultrasonic extraction and field-portable anodic stripping voltammetry of lead from environmental samples [J].
Ashley, K .
ELECTROANALYSIS, 1995, 7 (12) :1189-1192
[8]
Ultrasonic extraction and field-portable anodic stripping voltammetric measurement of lead in dust wipe samples [J].
Ashley, K ;
Wise, TJ ;
Mercado, W ;
Parry, DB .
JOURNAL OF HAZARDOUS MATERIALS, 2001, 83 (1-2) :41-50
[9]
ELECTROANALYTICAL APPLICATIONS IN OCCUPATIONAL AND ENVIRONMENTAL-HEALTH [J].
ASHLEY, K .
ELECTROANALYSIS, 1994, 6 (10) :805-820
[10]
Biosensors designed for environmental and food quality control based on screen-printed graphite electrodes with different configurations [J].
Avramescu, A ;
Andreescu, S ;
Noguer, T ;
Bala, C ;
Andreescu, D ;
Marty, JL .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 374 (01) :25-32