Simultaneous extraction of di(2-ethylhexyl) phthalate and nonionic surfactants from house dust - Concentrations in floor dust from 15 Danish schools

被引:67
作者
Clausen, PA
Bille, RLL
Nilsson, T
Hansen, V
Svensmark, B
Bowadt, S
机构
[1] Natl Inst Occupat Hlth, DK-2100 Copenhagen, Denmark
[2] Lund Univ, Dept Analyt Chem, S-22100 Lund, Sweden
[3] DHI Water & Environm, DK-2970 Horsholm, Denmark
[4] Univ Copenhagen, Dept Chem, DK-2100 Copenhagen, Denmark
[5] European Commiss, Res Directorate B7 3 12, B-1049 Brussels, Belgium
关键词
extraction methods; dust; diethylhexyl phthalate; phthalates; surfactants;
D O I
10.1016/S0021-9673(02)02007-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Static extraction, supercritical fluid extraction (SFE), pressurized liquid extraction (PLE) and Soxhlet extraction were compared for simultaneous extraction of di(2-ethylhexyl) phthalate (DEHP) and nonionic surfactants from house dust. Homogenized office floor dust from a vacuum cleaner dust bag ("standard dust") was used for the evaluation. One portion of the extracts was used for analysis of nonionic surfactants with LC-MS and another portion was used for DEHP analysis with GC-MS. The extraction yield of DEHP was comparable for all the methods whereas SFE and PLE were the most efficient extraction techniques for the nonionic surfactants. The PLE extraction was found most suitable as a routine method for simultaneous extraction of both types of compounds and was used in a field study of floor dust from 15 Danish schools. The mean concentration of DEHP in the school dust samples was similar to4 times higher than observed in other studies of dust from homes in different countries. The concentrations of nonionic surfactants were one order of magnitude lower than soap and linear alkylbenzene sulfonates measured in other studies of floor dust from offices and other public buildings. However, for the first time nonionic surfactants have been identified in house dust. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:179 / 190
页数:12
相关论文
共 25 条
[1]   Pressurised liquid extraction of persistent organic pollutants in environmental analysis [J].
Björklund, E ;
Nilsson, T ;
Bowadt, S .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2000, 19 (07) :434-445
[2]  
BOWADT S, 1995, J CHROMATOGR A, V703, P571
[3]  
Butte W, 2001, GEFAHRST REINHALT L, V61, P19
[4]   Gas chromatographic analysis of free fatty acids and fatty acid salts extracted with neutral and acidified dichloromethane from office floor dust [J].
Clausen, PA ;
Wilkins, K ;
Wolkoff, P .
JOURNAL OF CHROMATOGRAPHY A, 1998, 814 (1-2) :161-170
[5]  
CLAUSEN PA, 2002, UNPUB
[6]  
Clausen PA, 1999, P 8 INT C IND AIR QU, V2, P434
[7]   Study of adjuvant effect of model surfactants from the groups of alkyl sulfates, alkylbenzene sulfonates, alcohol ethoxylates and soaps [J].
Clausen, SK ;
Sobhani, S ;
Poulsen, OM ;
Poulsen, LK ;
Nielsen, GD .
FOOD AND CHEMICAL TOXICOLOGY, 2000, 38 (11) :1065-1074
[8]   Routine analysis of alcohol and nonylphenol polyethoxylates in wastewater and sludge using liquid chromatography-electro spray mass spectrometry [J].
Cohen, A ;
Klint, K ;
Bowadt, S ;
Persson, P ;
Jönsson, JÅ .
JOURNAL OF CHROMATOGRAPHY A, 2001, 927 (1-2) :103-110
[9]   DUST AND THE SICK BUILDING SYNDROME [J].
GYNTELBERG, F ;
SUADICANI, P ;
NIELSEN, JW ;
SKOV, P ;
VALBJORN, O ;
NIELSEN, PA ;
SCHNEIDER, T ;
JORGENSEN, O ;
WOLKOFF, P ;
WILKINS, CK ;
GRAVESEN, S ;
NORN, S .
INDOOR AIR, 1994, 4 (04) :223-238
[10]   EFFECT OF SFE FLOW-RATE ON EXTRACTION RATES - CLASSIFYING SAMPLE EXTRACTION BEHAVIOR [J].
HAWTHORNE, SB ;
GALY, AB ;
SCHMITT, VO ;
MILLER, DJ .
ANALYTICAL CHEMISTRY, 1995, 67 (15) :2723-2732