Large tip electrodes for successful elimination of atrial flutter resistant to conventional catheter ablation

被引:25
作者
Ventura, R [1 ]
Willems, S [1 ]
Weiss, C [1 ]
Flecke, J [1 ]
Risius, T [1 ]
Rostock, T [1 ]
Hoffmann, M [1 ]
Meinertz, T [1 ]
机构
[1] Univ Hamburg, Hosp Eppendorf, Dept Cardiol, D-20246 Hamburg, Germany
关键词
resistant; atrial flutter; ablation; long-tip catheter;
D O I
10.1023/A:1023665002255
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The most widely accepted criterion for successful radiofrequency catheter (RFC) ablation of typical atrial flutter is the development of bi-directional isthmus block. In a subset of patients, conventional RFC ablation fails to achieve this endpoint because deeper and wider lesions are required. We investigated the efficacy of a long 8-mm tip catheter in these cases. One hundred and seventy-four consecutive patients (137 male; 61 +/- 9 years) with recurrent typical atrial flutter underwent conventional RFC ablation first with a standard 4 mm tip catheter. In resistant cases (n = 52), ablation was continued using a large tip 8-mm catheter when the 4-mm tip catheter failed. Resistant atrial flutter was identified when 21 RFC pulses failed to reach the selected endpoint of bi-directional isthmus block or in cases of transient bi-directional block (at least 3 episodes). In 122 of the 174 patients (70%) conventional atrial flutter ablation was successfully performed with 13 +/- 5 RFC applications. In the remaining 52 subjects (30%), the ablation procedure was completed using the large tip electrode catheter. In 30 of these 52 patients (58%), the catheter was changed because of persistent intra-atrial conduction after 21 RFC pulses and in 22 (42%) because of intermittent conduction block after 11 +/- 5 applications. Using the large tip electrode catheter, the selected endpoint was achieved in all patients of both groups with 3 +/- 2 RFC pulses (power output of 50-60 W, pulse duration of 60 sec). No post-procedure complications were observed. After 15 +/- 5 months of follow-up, 16 patients (9%) had recurrence of atrial flutter. Five of the patients had been in the resistant group. In patients with atrial flutter resistant to conventional ablation therapy, the long tip (8-mm) catheter appears to be a safe and effective alternative to use of the conventional 4-mm tip catheter.
引用
收藏
页码:149 / 154
页数:6
相关论文
共 25 条
[1]   The architecture of the atrial musculature between the orifice of the inferior caval vein and the tricuspid valve: The anatomy of the isthmus [J].
Cabrera, JA ;
Sanchez-Quintana, D ;
Ho, SY ;
Medina, A ;
Anderson, RH .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1998, 9 (11) :1186-1195
[2]  
Cabrera Jose A., 1999, Journal of the American College of Cardiology, V33, p164A
[3]   Electrophysiological effects of catheter ablation of inferior vena cava-tricuspid annulus isthmus in common atrial flutter [J].
Cauchemez, B ;
Haissaguerre, M ;
Fischer, B ;
Thomas, O ;
Clementy, J ;
Coumel, P .
CIRCULATION, 1996, 93 (02) :284-294
[4]   RADIOFREQUENCY ABLATION OF THE INFERIOR VENA-CAVA - TRICUSPID-VALVE ISTHMUS IN COMMON ATRIAL-FLUTTER [J].
COSIO, FG ;
LOPEZGIL, M ;
GOICOLEA, A ;
ARRIBAS, F ;
BARROSO, JL .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (08) :705-709
[5]   RADIOFREQUENCY CATHETER ABLATION FOR THE TREATMENT OF HUMAN TYPE-1 ATRIAL-FLUTTER - IDENTIFICATION OF A CRITICAL ZONE IN THE REENTRANT CIRCUIT BY ENDOCARDIAL MAPPING TECHNIQUES [J].
FELD, GK ;
FLECK, RP ;
CHEN, PS ;
BOYCE, K ;
BAHNSON, TD ;
STEIN, JB ;
CALISI, CM ;
IBARRA, M .
CIRCULATION, 1992, 86 (04) :1233-1240
[6]   Radiofrequency catheter ablation of common atrial flutter in 200 patients [J].
Fischer, B ;
Jais, P ;
Shah, DP ;
Chouairi, S ;
Haissaguerre, M ;
Garrigues, S ;
Poquet, F ;
Gencel, L ;
Clementy, J ;
Marcus, FI .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1996, 7 (12) :1225-1233
[7]   Successful irrigated-tip catheter ablation of atrial flutter resistant to conventional radiofrequency ablation [J].
Jaïs, P ;
Haïssaguerre, M ;
Shah, DC ;
Takahashi, A ;
Hocini, M ;
Lavergne, T ;
Lafitte, S ;
Le Mouroux, A ;
Fischer, B ;
Clémenty, J .
CIRCULATION, 1998, 98 (09) :835-838
[8]   Activation and entrainment mapping defines the tricuspid annulus as the anterior barrier in typical atrial flutter [J].
Kalman, JM ;
Olgin, JE ;
Saxon, LA ;
Fisher, WG ;
Lee, RJ ;
Lesh, MD .
CIRCULATION, 1996, 94 (03) :398-406
[9]   Comparison of effectiveness of an 8-mm versus a 4-mm tip electrode catheter for radiofrequency ablation of typical atrial flutter [J].
Kasai, A ;
Anselme, F ;
Tee, WS ;
Cribier, A ;
Saoudi, N .
AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (09) :1029-1032
[10]   TEMPERATURE-GUIDED RADIOFREQUENCY CATHETER ABLATION WITH VERY LARGE DISTAL ELECTRODES [J].
LANGBERG, JJ ;
GALLAGHER, M ;
STRICKBERGER, SA ;
AMIRANA, O .
CIRCULATION, 1993, 88 (01) :245-249