Intraoperative sentinel lymph node mapping of the lung using near-infrared fluorescent quantum dots

被引:218
作者
Soltesz, EG
Kim, S
Laurence, RG
DeGrand, AM
Parungo, CP
Dor, DM
Cohn, LH
Bawendi, MG
Frangioni, JV
Mihaljevic, T
机构
[1] Brigham & Womens Hosp, Dept Surg, Div Cardiac Surg, Boston, MA 02115 USA
[2] MIT, Dept Chem, Cambridge, MA 02139 USA
[3] Beth Israel Deaconess Med Ctr, Div Hematol Oncol, Boston, MA 02215 USA
[4] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
关键词
D O I
10.1016/j.athoracsur.2004.06.055
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The presence of lymph node metastases is an important prognostic marker with regard to non-small-cell lung cancer (NSCLC). Assessment of the sentinel lymph node (SLN) for the presence of tumor may improve staging. Our objective was to develop an optical noninvasive imaging tool that would permit intraoperative SLN mapping and provide real-time visual feedback for image-guided localization and resection. Methods. Invisible near-infrared (NIR) light penetrates relatively deeply into tissue and background autofluorescence is low. We have developed a NIR fluorescence imaging system that simultaneously displays color video and NIR images of the surgical field. We recently engineered 15 nm nonradioactive NIR fluorescent quantum dots (QDs) as optimal lymphotrophic optical probes. The introduction of these QDs into lung tissue allows real-time visualization of draining lymphatic channels and nodes. Results. In 12 Yorkshire pigs (mean weight 35 kg) we demonstrated that 200 pmol of NIR QDs injected into lobar parenchyma accurately maps lymphatic drainage and the SLN. All SLNs were strongly fluorescent and easily visualized within 5 minutes of injection. In 14 separate injections QDs localized to a mediastinal node, whereas in 2 injections QDs localized to a hilar intraparenchymal node. Histologic analysis in all cases confirmed the presence of nodal tissue. Conclusions. We report a highly sensitive rapid technique for SLN mapping of the lung. This technique permits precise real-time imaging and therefore overcomes many limitations of currently available techniques.
引用
收藏
页码:269 / 277
页数:9
相关论文
共 27 条
[1]   Lymphoscintigraphy, the sentinel node concept, and the intraoperative gamma probe in melanoma, breast cancer, and other potential cancers [J].
Alazraki, NP ;
Eshima, D ;
Eshima, LA ;
Herda, SC ;
Murray, DR ;
Vansant, JP ;
Taylor, AT .
SEMINARS IN NUCLEAR MEDICINE, 1997, 27 (01) :55-67
[2]   MEDIASTINAL LYMPH-NODE DISSECTION IN RESECTED LUNG-CANCER - MORBIDITY AND ACCURACY OF STAGING [J].
BOLLEN, ECM ;
VANDUIN, CJ ;
THEUNISSEN, PHMH ;
VANTHOFGROOTENBOER, BE ;
BLIJHAM, GH .
ANNALS OF THORACIC SURGERY, 1993, 55 (04) :961-966
[3]  
CABANAS RM, 1977, CANCER, V39, P456, DOI 10.1002/1097-0142(197702)39:2<456::AID-CNCR2820390214>3.0.CO
[4]  
2-I
[5]   Guidelines for sentinel node biopsy and lymphatic mapping of patients with breast cancer [J].
Cox, CE ;
Pendas, S ;
Cox, JM ;
Joseph, E ;
Shons, AR ;
Yeatman, T ;
Ku, NN ;
Lyman, GH ;
Berman, C ;
Haddad, F ;
Reintgen, DS .
ANNALS OF SURGERY, 1998, 227 (05) :645-653
[6]   An operational near-infrared fluorescence imaging system prototype for large animal surgery [J].
De Grand, AM ;
Frangioni, JV .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2003, 2 (06) :553-562
[7]   In vivo near-infrared fluorescence imaging [J].
Frangioni, JV .
CURRENT OPINION IN CHEMICAL BIOLOGY, 2003, 7 (05) :626-634
[8]   Current status of sentinel lymph node mapping and biopsy: Facts and controversies [J].
Jakub, JW ;
Pendas, S ;
Reintgen, DS .
ONCOLOGIST, 2003, 8 (01) :59-68
[9]   Near-infrared fluorescent type II quantum dots for sentinel lymph node mapping [J].
Kim, S ;
Lim, YT ;
Soltesz, EG ;
De Grand, AM ;
Lee, J ;
Nakayama, A ;
Parker, JA ;
Mihaljevic, T ;
Laurence, RG ;
Dor, DM ;
Cohn, LH ;
Bawendi, MG ;
Frangioni, JV .
NATURE BIOTECHNOLOGY, 2004, 22 (01) :93-97
[10]  
Lim Yong Taik, 2003, Mol Imaging, V2, P50, DOI 10.1162/153535003765276282