Analysis of heat conservation during copper sulphide heap leaching

被引:86
作者
Dixon, DG [1 ]
机构
[1] Univ British Columbia, Dept Met & Mat Engn, Vancouver, BC V6T 1Z4, Canada
关键词
heat conservation; copper sulphide; heap leaching;
D O I
10.1016/S0304-386X(00)00119-5
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
An analysis of heat conservation during copper sulphide heap leaching has been carried out with the aid of a computer model. As a result, a new mode of heap behaviour called "evaporative autocatalysis" is postulated. In this mode, air is blown upward through the heap at a rate sufficient to drive the net advection of heat upward through the heap, resulting in much higher and more uniform internal heap temperatures than can be achieved in the absence of forced aeration. The effects of flow rate, heat generation rate, solution and air heating, and application of an evaporation shield to the heap surface are also investigated. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:27 / 41
页数:15
相关论文
共 5 条
  • [1] Bolorunduro S. A., 1999, THESIS U BRIT COLUMB
  • [2] CASAS JM, 1995, BIOHYDROMETALLURGICA, V1, P447
  • [3] Cathles L. M., 1975, Metallurgical Transactions B (Process Metallurgy), V6B, P617, DOI 10.1007/BF02913857
  • [4] Marcantonio P. J., 1976, THESIS U UTAH
  • [5] RATE-LIMITING FACTORS IN DUMP LEACHING OF PYRITIC ORES
    PANTELIS, G
    RITCHIE, AIM
    [J]. APPLIED MATHEMATICAL MODELLING, 1992, 16 (10) : 553 - 560