Reduction of blurring in view angle tilting MRI

被引:91
作者
Butts, K
Pauly, JM
Gold, GE
机构
[1] Lucas Ctr, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Radiol, Stanford, CA USA
[3] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
关键词
magnetic resonance imaging; view angle tilting; distortion correction; metal artifact; magnetic susceptibility artifact;
D O I
10.1002/mrm.20375
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance imaging (MRI) in the presence of metallic objects suffers from slice-selection errors and in-plane distortions. View angle tilting (VAT) corrects for in-plane distortions by adding a gradient on the slice-select axis during readout, but can suffer from image blurring. This work demonstrates that the major source of blurring is a slice profile modulation of the data, and proposes several solutions to prevent such blurring. Multiple high-bandwidth readouts are demonstrated to reduce the blurring while improving the signal-to-noise ratio (SNR) over a single high-bandwidth readout. (C) 2005 Wiley-Liss, Inc.
引用
收藏
页码:418 / 424
页数:7
相关论文
共 22 条
[1]  
Butts K, 1999, JMRI-J MAGN RESON IM, V9, P586, DOI 10.1002/(SICI)1522-2586(199904)9:4<586::AID-JMRI13>3.0.CO
[2]  
2-X
[3]   NONSUSCEPTIBILITY ARTIFACTS DUE TO METALLIC OBJECTS IN MR-IMAGING [J].
CAMACHO, CR ;
PLEWES, DB ;
HENKELMAN, RM .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (01) :75-88
[4]   TOTAL INHOMOGENEITY CORRECTION INCLUDING CHEMICAL-SHIFTS AND SUSCEPTIBILITY BY VIEW ANGLE TILTING [J].
CHO, ZH ;
KIM, DJ ;
KIM, YK .
MEDICAL PHYSICS, 1988, 15 (01) :7-11
[5]   Design of symmetric-sweep spectral-spatial RF pulses for spectral editing [J].
Cunningham, CH ;
Vigneron, DB ;
Chen, AP ;
Xu, D ;
Hurd, RE ;
Sailasuta, N ;
Pauly, JM .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (01) :147-153
[6]   The use of view angle tilting to reduce distortions in magnetic resonance imaging of cryosurgery [J].
Daniel, BL ;
Butts, K .
MAGNETIC RESONANCE IMAGING, 2000, 18 (03) :281-286
[7]  
Duerk J L, 2000, Top Magn Reson Imaging, V11, P147, DOI 10.1097/00002142-200006000-00001
[8]   Quantitative evaluation of metal artifact reduction techniques [J].
Kolind, SH ;
MacKay, AL ;
Munk, PL ;
Xiang, QS .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (03) :487-495
[9]   Optimized outer volume suppression for single-shot fast spin-echo cardiac imaging [J].
Le Roux, P ;
Gilles, RJ ;
McKinnon, GC ;
Carlier, PG .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (05) :1022-1032
[10]   Quantitative assessment of an MR technique for reducing metal artifact: application to spin-echo imaging in a phantom [J].
Lee, MJ ;
Janzen, DL ;
Munk, PL ;
MacKay, A ;
Xiang, QS ;
McGowen, A .
SKELETAL RADIOLOGY, 2001, 30 (07) :398-401